Bleeding
PVG 120 installed vertically
*
190[7.48]
*
100[3.94]
T
LX
PP
V310105.A
If the group is installed vertically, it is recommended to bleed it at the adjusting screws.
PVPE/PVH relief valves
Max. tightening torque for PVPE/PVH
Position
Across flats
Max. tightening torque
1
22 mm [0.87 in]
5 N•m [45 lbf•in]
2
36 mm [1.42 in]
85 N•m [750 lbf•in]
3
36 mm [1.42 in]
85 N•m [750 lbf•in]
Tightening PVPE/PVH
S
MA
P
2.5[0.098]
2 Nm
[17.5 lbf•in)
L
PVP
PVPH
2
LS
LS
V310157.A
1
PVPE
Service Manual
PVG 120 Proportional Valve Group
Installation
20