background image

© Danfoss A/S, 2015-02 

11038042

 • Rev BC • Feb 2015 

3

Connections, pump side modul, PVP 

basic module PVB end plate, PVS

E101 285E

B

A

P

LS

T0

P

Accu

LX

Maximum tightening torque 

 

G 3/4 

G 1 

G 3/4 

G 1/4 

G 1 

G 1 1/4

 

210 Nm 

330 Nm 

210 Nm 

40 Nm 

330 Nm 

540 Nm

 

1850 lbf

·

in  2920 lbf

·

in 

1850 lbf

·

in 

350 lbf

·

in 

2920 lbf

·

in 

4780 lbf

·

in

 

50 Nm 

70 Nm 

50 Nm 

20 Nm 

70 Nm 

100 Nm

 

445 lbf

·

in 

620 lbf

·

in 

445 lbf

·

in 

180 lbf

·

in 

620 lbf

·

in 

885 lbf

·

in

 

110 Nm 

150 Nm 

110 Nm 

30 Nm 

150 Nm 

240 Nm

 

970 lbf

·

in  1330 lbf

·

in 

970 lbf

·

in 

270 lbf

·

in 

1330 lbf

·

in 

2125 lbf

·

in

 

210 Nm 

330 Nm 

210 Nm 

40 Nm 

330 Nm 

540 Nm

 

1850 lbf

·

in  2920 lbf

·

in 

1850 lbf

·

in 

350 lbf

·

in 

2920 lbf

·

in 

4780 lbf

·

in

 

1 1/16 in-12  1 5/16 in-12  1 1/16 in-12 

9/16 in-18 

1 5/16 in-12 

1 5/8 in-12

 

120 Nm 

160 Nm 

120 Nm 

40 Nm 

160 Nm 

320 Nm

 

1040 lbf

·

in  1420 lbf

·

in 

1040 lbf

·

in 

350 lbf

·

in 

1420 lbf

·

in 

2830 lbf

·

in

Connection

BSPP port connection

With steel washer

With copper washer

With aluminum washer

With cutting edge

UNF port connection

With O-ring

  

 

LS, LX, T0 

 

A/B 

Gauge: P, Pp,  

T

 

P

p

 Accum.

P

p

 gauge

P

gauge

(PVP-OC)

PVP-OC shown

Product

Rated pressure

PVG 100

350 bar [5076 psi]

PVG 100 w. HIC steel

350 bar [5076 psi]

PVG 100 w. HIC aluminium

210 bar [3046 psi]

PVG 100/32 w. PVBZ

210 bar [3046 psi]

PVG 100/32 w. PVS

300 bar [4351 psi]

PVG 100/32 w. PVSI

350 bar [5076 psi]

Rated pressure

Summary of Contents for PVG 100

Page 1: ...allation an plug orientation 118 4 65 170 6 69 100 4 100 4 170 6 69 L PVP M12 x 14 0 4 places Room for dismantling 60 Nm 530 lbf in 60 Nm 530 lbf in P106 000E T A B P DIN mounting orientation Modul og PVB 1 2 3 4 5 6 7 8 L mm 80 0 128 0 176 0 224 0 272 0 320 0 368 0 416 0 L in 3 15 5 04 6 93 8 82 10 71 12 60 14 49 16 38 ...

Page 2: ...H PVMD PVMR PVMF PVP PVM PVB PVS B A P A P B 6 1 N m 53 9 lbf in Q max P B Q max P A 01 03 A 00 0299 Week of manufacture Year of manufacture Day of the week A Monday B Tuesday Issue number Series number C PVG code number week and year of manufacture D PVP pressure setting 6 1 N m 53 9 lbf in 10 mm 3 mm Q max B Q max A Q max B Q max A Q max A Q max B C D ...

Page 3: ...210 Nm 40 Nm 330 Nm 540 Nm 1850 lbf in 2920 lbf in 1850 lbf in 350 lbf in 2920 lbf in 4780 lbf in 1 1 16 in 12 1 5 16 in 12 1 1 16 in 12 9 16 in 18 1 5 16 in 12 1 5 8 in 12 120 Nm 160 Nm 120 Nm 40 Nm 160 Nm 320 Nm 1040 lbf in 1420 lbf in 1040 lbf in 350 lbf in 1420 lbf in 2830 lbf in Connection BSPP port connection With steel washer With copper washer With aluminum washer With cutting edge UNF por...

Page 4: ... 11038042 Rev BC Feb 2015 Danfoss A S 2015 02 Installation of lever P106 007E Base with an angle of 22 5 Base with an angle of 37 5 Pressure setting P106 008E PVP CC PVP OC 360 120 bar 360 1740 psi 4 mm ...

Page 5: ...ction B Turn of transducer Movement of lever 1 4 1 2 3 4 1 5 mm 0 06 in 3 0 mm 0 12 in 4 5 mm 0 18 in PVEH PVEM PVES Adjestment of PVE when max lever travel is exceeded PVE is factory preset Check maximum lever travel in neutral position 1 Make sure the system is supplied with hydraulic power 2 Connect supply voltage UDC Signal voltage 0 5 UDC or cut off th signal volatage US on pin 2 ...

Page 6: ...076 bar Max coil surface temperature 155 C 311 F Rated voltage 12 V __ 24 V __ Current consumtion 22 C 71 6 F coil temperature 1 55 A 0 78 A 110 C 230 F coil temperature 1 00 A 0 50 A Power consumtion 22 C 71 6 F coil temperature 19 W 19 W 110 C 230 F coil temperature 12 W 12 W Max permissible deviation from rated supply voltage 10 Across flats P106 004E 1 cartridge valve 2 coil nut Installation a...

Page 7: ...5 Nm 1 42 in 750 lbf in Max operation pressure 350 bar 5076 bar Max coil surface temperature 155 C 311 F Rated voltage 12 V __ 24 V __ Current consumtion 22 C 71 6 F coil temperature 1 55 A 0 78 A 110 C 230 F coil temperature 1 00 A 0 50 A Power consumtion 22 C 71 6 F coil temperature 19 W 19 W 110 C 230 F coil temperature 12 W 12 W Max permissible deviation from rated supply voltage 10 Across fla...

Page 8: ...8 11038042 Rev BC Feb 2015 Danfoss A S 2015 02 PVMR Disassembly P106 005 1 2 3 4 ...

Page 9: ...eb 2015 9 PVMR F Assembly P106 006 1 2 3 4 Y X X X X Z Z X Y Z 8 0 5 Nm 15 2 Nm 4 1 Nm Tightening torque 70 4 5 lbf in 135 20 lbf in 35 9 lbf in Width across flats 5 mm 36 mm 11 mm PVMF 19 mm PVMR Tightening torques and widths across flats ...

Page 10: ...10 11038042 Rev BC Feb 2015 Danfoss A S 2015 02 Standard main spool assembly for PVMR E101 291E 3 4 8 Nm 70 lbf in 8 Nm 70 lbf in 12 mm 11 mm 1 2 12 5 mm ...

Page 11: ...foss A S 2015 02 11038042 Rev BC Feb 2015 11 Standard float spool assembly for PVMR E101 290E 8 Nm 70 lbf in P A F 11 mm 8 Nm 70 lbf in 12 mm Not Spools must be installed with LS holes on B port side of PVB ...

Page 12: ...12 11038042 Rev BC Feb 2015 Danfoss A S 2015 02 ...

Reviews: