178 | © Danfoss | August 2018
AQ00000211
ENGINEERING TOMORROW
Calibration procedure
The following steps describes a calibration procedure, which can be obtained or could be implemented in a service tool.
Refer Figure 69 for below steps.
1.
The calibration operator inputs two initial experimental main spool set-points
S1
and
S2
which the calibration
algorithm alternates between.
2.
The starting point for the measurement is when the steered wheel angle is at Calib_WA_L.
3.
The calibration algorithm applies main spool set-point
S1
to initiate a steering direction towards right.
4.
The time
T1
it takes for the steered wheels to reach Calib_WA_R is measured and denoted
TR
.
5.
When the steered wheels reaches Calib_WA_R, the calibration algorithm applies main spool set-point
S2
to
initiate a steering direction towards left.
6.
The time
T2
it takes for the steered wheels to reach Calib_WA_L is measured and denoted
TL
.
7.
The calibration operator continuously evaluates
TR
and
TL
and stepwise increases or decreases the spool set-
points
S1
and
S2
.
8.
Repeat from step 3 until
TR
and
TL
meets the success criteria described in section 17.6.5.2 and shown as
T3
and
T4
).
Figure 69
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...