![Danfoss PVE 4 Series Technical Information Download Page 43](http://html1.mh-extra.com/html/danfoss/pve-4-series/pve-4-series_technical-information_4063565043.webp)
Control (U
S
) for standard mounted PVEH /PVEM float B, 4–pin version
Function
Voltage relative
PWM
Neutral
0,5 • U
DC
50%
Q: P
→
A
0,5
→
0,34 • U
DC
50%
→
34%
Q: P
→
B
0,5
→
0,65 • U
DC
50%
→
65%
Float
0,75 • U
DC
75%
PVEM is not PLUS+1
®
compliant.
PVE standard connections
AMP version
Hirschmann/DIN
Used for PVEA/PVEH/PVES/PVEU.
Used for PVEH/PVEM/PVES/PVEH float B/PVEM float
B.
Deutsch version
LED
Used for PVEA/PVEH/PVES/PVEU/PVEH float B.
Standard PVE with DI
Connection PVE with direction indication (DI)
Connector 1
U
S
U
DC1
Gnd
Error
AMP (grey)
p 1
p 2
p 3
p 4
Deutsch
p 1
p 4
p 3
p 2
Connector 2
DI-B
DI-A
Gnd
U
DC2
AMP (black)
p 1
p 2
p 3
p 4
Deutsch
p 4
p 3
p 2
p 1
Technical Information
PVE, Series 4 for PVG 32/100/120 and PVHC
Technical Data
520L0553 • Rev GD • Jan 2014