![background image](http://html1.mh-extra.com/html/danfoss/plus-1-connect-cs500/plus-1-connect-cs500_manual_3424004015.webp)
ECUs. The input function can be used, for example, to read and log status information from devices or
machines as well as to directly determine and monitor switch and key states. The data can be sent from
the input/output function via the CAN bus or via the mobile radio network.
CAN interfaces
The device features 2 CAN bus interfaces. The CAN interfaces meet the specifications CAN 2.0 A/B
protocol and the physical layer according to ISO 11898-2 high-speed up to 1 Mbit / s. The CAN interfaces
are operational only when existing power supply is energized. A support for CAN-FD is not possible.
Device configuration
The CS500 can be remotely configured from the Danfoss PLUS+1
®
Connect portal, PLUS+1
®
Service Tool,
or programmatically with PLUS+1
®
GUIDE to monitor the machine state, performance, and position. Both
position and machine data are periodically transmitted and stored to the Danfoss Data Portal.
CS500 firmware update
A firmware update to the CS500 can be loaded via the Danfoss PLUS+1
®
Connect portal. The firmware
update may reset the saved configuration to default. After the firmware update, load your configuration
to the device through the PLUS+1
®
Connect portal.
Secure connection to the PLUS+1
®
Connect portal
CS500 always establishes a secure encrypted TLS connection to the PLUS+1
®
Connect portal. If, for
specific reasons, the encryption is a problem, please contact a Danfoss representative for possible
solutions.
Technical Information
PLUS+1® Connect CS500 IoT Gateway
Device functions
©
Danfoss | October 2021
BC397226723595en-000101en-000101 | 15