Service guide
Disassembling and assembling PAHT / PAHT G 20-32
3
180R9175 / 521B1108 / DKCFN.PI.012.E3.02 / 01.2016
1. Disassembling the
pump
2. Loosen and remove 6 screws.
1. Tools required for dismantling the pump.
3. Remove mounting flange.
4. Remove shaft sealing.
Caution: Avoid scratching the sealing
surface on the shaft.
5. Remove spring.
6. Remove 2 guide pins.