521B1072
DKCFN.PI.011.NC3.02
09-2013
INSTRUCTIONS
Servicing PAH 50 - 100
18
0R
90
98
18
0R
90
98
Note: If the pump is dismantled during the warranty
period, the pump is no longer under warranty.
Dismantling:
1. Tools required for dismantling the PAH 50 - 100 pump.
2. Remove parallel key and unscrew front screw M6 (10 mm key).
3. Unscrew screws in front flange.
4. Remove front flange.
5. Remove shaft seal using two screwdrivers.
6. Remove guide pin from housing and the two guide pins from
swash plate.