•  DIN rail mounting complying with EN 60715
•  Self extinguishing V0 according to IEC 60695-11-10 and glowing/hot wire test at 960 °C according to IEC 60695-2-12
•  Ball test: 125 °C according to IEC 60730-1. Leakage current: ≥ 250 V according to IEC 60112

Other features

•  Operating conditions CE: -20T60 / UL: 0T55, 90% RH non-condensing
•  Storage conditions: -30T80, 90% RH non-condensing
•  To be integrated in Class I and/or II appliances
•  Index of protection: IP40 only on the front cover
•  Period of electric stress across insulating parts: long
•  Suitable for use in environments with degree of pollution 2
•  Category of resistance to heat and fire: D
•  Immunity against voltage surges: category II
•  Software class and structure: class A

Compliance

This product is designed to comply with the following EU standards:
•  Low voltage directive LVD 2014/35/EU:

 

– EN60730-1: 2011 (Automatic electrical control for household and similar use. General requirements)

 

– EN60730-2-9: 2010 (Particular Requirements for Temperature Sensing Controls)

•  Electromagnetic compatibility EMC directive 2014/30/EU: 

 

– EN 61000-6-3: 2007 +A1: 2011 (Emission standard for residential, commercial and light-industrial environments)

 

– EN 61000-6-2: 2005 (Immunity for industrial environments)

•  RoHS directive 2011/65/EU and 2015/863/EU:

 

– EN50581: 2012

UL approval:
•  UL file E31024

General warnings

•  Every use that is not described in this manual is considered incorrect and is not authorised by the manufacturer
•  Verify that the installation and operating conditions of the device respect the ones specified in the manual, specially concerning the 

supply voltage and environmental conditions

•  This device contains live electrical components therefore all the service and maintenance operations must be performed by qualified 

personnel

•  The device can’t be used as a safety device
•  Liability for injury or damage caused by the incorrect use of the device lies solely with the user

Installation warnings

•  Mounting position recommended: vertical
•  The installation must be executed according the local standards and legislation of the country
•  Always operate on the electrical connections with the device disconnected from the main power supply
•  Before carrying out any maintenance operations on the device, disconnect all the electrical connections
•  For safety reasons the appliance must be fitted inside an electrical panel with no live parts accessible
•  Don’t expose the device to continuous water sprays or to relative humidity greater than 90%. 

Avoid exposure to corrosive or pollutant gases, natural elements, environments where explosives or mixes of flammable gases are 

present, dust, strong vibrations or chock, large and rapid fluctuations in ambient temperature that in combination with high humidity 

can condensate, strong magnetic and/or radio interference (e.g. transmitting antennae)

•  When connecting loads beware of the maximum current for each relay and connector
•  Use cable ends suitable for the corresponding connectors. After tightening the screws of connectors, slightly tug the cables to check 

their tightness

•  Use appropriate data communication cables. Refer to the Fieldbus Installation Guide for the kind of cable to be used and setup 

recommendations

•  Reduce the path of the probe and digital inputs cables as much as possible, and avoid spiral paths enclosing power devices. Separate 

from inductive loads and power cables to avoid possible electromagnetic noises

•  Avoid touching or nearly touching the electronic components fitted on the board to avoid electrostatic discharges

 

Disposal instruction

Equipment containing electrical components may not be disposed together with domestic waste. It must be separately collected 

with electrical and electronic waste according to local and valid legislation.

Summary of Contents for MCX08M2

Page 1: ...2 with TTL ANALOG INPUTS NTC 0 1 V 0 5 V 0 10 V PT1000 selectable via software 4 Universal NTC Pt1000 0 1 V 0 5 V 0 10 V ON OFF 0 20 mA 4 20 mA selectable via software 4 Total number 8 DIGITAL INPUTS Voltage free contact 8 Total number 8 ANALOG OUTPUTS 0 10 V DC optoinsulated 2 0 10 V DC PWM PPM selectable via software 2 Total number 4 DIGITAL OUTPUTS SPST relay 16 A normally open contacts 2 SPST ...

Page 2: ...ust be performed by qualified personnel The device can t be used as a safety device Liability for injury or damage caused by the incorrect use of the device lies solely with the user Installation warnings Mounting position recommended vertical The installation must be executed according the local standards and legislation of the country Always operate on the electrical connections with the device ...

Page 3: ...C optoins 2 AO3 AO4 Analog outputs optoinsulated 0 10 V DC minimum load 1K Ω 10 mA for each output PWM PPM 0 10VDC 2 AO1 AO2 Analog outputs selectable via software between 0 10 V dc minimum load 1K Ω 10 mA for each output pulsing output synchronous with the line at modulation of impulse position PPM or modulation of impulse width PWM pulsing output at modulation of impulse position PPM with range ...

Page 4: ...CX08M2 TOP PWM PPM 0 10 Vdc 0 10 V optoinsulated NTC 0 1 V 0 5 V 0 10 V PT1000 To the AI 100 mA max To the AI 120 mA max Not used RX TX DIR 5V AUX COM TTL only for 080G0335 MCX08M2 TOP MCX08M2 BOTTOM NTC 0 1 V 0 5 V 0 10 V PT1000 AI max To the AI 120 mA max Danfoss 80G8036 04 DIR 5V AUX 0G0335 ...

Page 5: ... plug in connector type pitch 5 mm section cable 0 2 2 5 mm Digital input 1 8 connector 10 way screw plug in connector type pitch 5 mm section cable 0 2 2 5 mm Analog input 5 8 connector 5 way screw plug in connector type pitch 5 mm section cable 0 2 2 5 mm TTL connector only for 080G0335 5 way spring plug in connector type pitch 2 5 mm section cable 0 2 2 5 mm Bottom Board Power supply connector ...

Page 6: ...s DCS vt 2021 01 6 AN358818754869en 000201 Product part numbers Accessories part numbers Description Code No MCX08M CONNECTORS KIT 080G0180 Description Code No MCX08M2 230 V LCD RS485 TTL Single Pack 080G0335 ...

Reviews: