PUMP NEUTRAL ADJUSTMENT 

(continued)

PUMP PORT LOCATION

2000

Location of Pump Ports.

7.

If the transmission operates as indicated by motor shaft
rotation, reduce speed to idle. Using a 3 mm internal hex
wrench, slowly turn the null adjustment screw clockwise
or counterclockwise until the transmission does not
operate. Repeat step 6. Note that charge pressure
should drop with forward or reverse stroking of the pump
swashplate due to the shifting of the shuttle valve in the
motor manifold. Slowly turn the null adjustment screw
clockwise until charge pressure decreases.

8.

With a 3 or 4 mm (4 mm units built after April 95) internal
hex wrench, slowly turn the null adjustment screw
counterclockwise, observing the wrench angle rotation,
until charge pressure decreases again (charge pressure
will rise in neutral and drop when going into stroke).

9.

Turn the adjustment screw clockwise half the amount of

CUSTOMER SERVICE

NORTH AMERICA

ORDER FROM

Danfoss (US) Company
Customer Service Department
3500 Annapolis Lane North
Minneapolis, Minnesota  55447
Phone: (763) 509-2084
Fax: (763) 559-0108

DEVICE REPAIR

For devices in need of repair or evaluation, include a
description of the problem and what work you believe
needs to be done, along with your name, address and
telephone number.

RETURN TO

Danfoss (US) Company
Return Goods Department
3500 Annapolis Lane North
Minneapolis, Minnesota  55447

EUROPE

ORDER FROM

Danfoss (Neumünster) GMBH & Co.
Order Entry Department
Krokamp 35
Postfach 2460
D-24531 Neumünster
Germany
Phone: 49-4321-8710
Fax: 49-4321-871355

the turn observed in step 8. This should be the center of
neutral.

10. Hold the adjustment screw and securely tighten the hex

lock nut on the adjustment screw to 14-18 foot-pounds.
Note that if a motor is used that does not have a manifold,
neutral should be adjusted (steps 8 - 10) by observing
the motor shaft rotation without a load.

11. Stop the prime mover.

12. Reconnect the electrical signal source.

13. Run the system briefly to ensure that it operates

proportionally on both sides of null. Swashplate
movement can be verified by watching motor shaft
rotation without a load.

CASE DRAIN

CHARGE PRESSURE
GAUGE PORT

BLN-95-8995-4

Summary of Contents for MCV111B Series

Page 1: ...the pump s output while maintaining optimum dynamic response to control commands 1 PUMP SIZE MODEL CODE PUMP SIZE 03 30 cc 05 42 or 55 cc 07 75 cc 10 100 cc 13 130 cc Pump S N 92 19 14 130 cc Pump S N 92 19 18 25 180 or 250 cc BASE DEVICE PUMP SIZE PILOT STYLE 2 PILOT MODEL CODE PILOT STYLE 02 MS Connector 04 Packard Connector ORDERING INFORMATION The MCV111B Electrical Displacement Control is ord...

Page 2: ...ESSURE Typically 300 400 psi above case pressure RATINGS SCALE FACTOR 1 15 psi mA single coil 2 3 psi mA coils in series 1 15 psi mA coils in parallel TEMPERATURE The valve will meet all specifications over the range of 21 to 82 C 70 to 180 F TECHNICAL DATA ELECTRICAL CHARACTERISTICS Voltage to Terminal One of Dual Coils Dual Coils in Parallel Dual Coils in Series Input Produces Shaft Flow Out Rot...

Page 3: ...ERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 MS CONNECTOR OPTION PACKARD WEATHER PACK CONNECTOR OPTION DIMENSIONS 42 cc AND 55 cc PUMP EDC LOCK NUT MANUAL OPERATOR SAE SERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 CONTROL LINKAGE 10 4 0 41 22 4 0 88 27 94 1 10 52 83 2 08 203 2 8 00 8 6 REF 0 34 7 11 0 28 NEUTRAL ADJUST 7 14 DIA 6 PLACES 0 281 DIA 122 99 4 84 89 41 3 52 55 37 2 18 36 07 1 42 31...

Page 4: ...al pressure drop when the system is at null Between the nozzle and the orifice on each side is a control port As the torque motor shifts the flapper away from one nozzle toward the other a differential control pressure results the high side being the one nearer the flapper Fluid pressure rises on this side and moves the flapper back towards null When the torque output from the motor equals the tor...

Page 5: ... or if the pilot output pressure goes to case pressure Mechanical feedback must be present FREQUENCY RESPONSE EXCEPT FOR 130 cc PUMPS 2 Hz minimum with 052 pressure limiter orifices 3 Hz minimum without pressure limiter orifices with pressure limiters inoperative Under 500 1000 psi load at 90 phase lag with 10 mA signal at 45 mA offset TIME RESPONSE EXCEPT FOR 130 CC PUMPS 1 0 seconds 0 to full st...

Page 6: ...nnector order part number K08106 The mating Packard ENVIRONMENTAL HUMIDITY After being placed in a controlled atmosphere of 95 humidity at 49 C 120 F for 10 days the EDC will perform within specification limits Meets MIL STD 810B WIRING connector is a bag assembly part number K03384 comprised of 1 4 14 16 gauge sleeves 2 4 18 20 gauge sleeves 3 1 plastic housing 4 4 green cable seals accept 2 2 2 ...

Page 7: ...nsulation should just protrude beyond the seal 4 Select the larger of the two sets of pins as measured at Dimension A see the Dimension A drawing if using 14 16 gauge wire Choose the smaller if using 18 20 gauge Place the wire into the socket so that the seal edge is pushed through and extends slightly beyond the circular tabs that hold it in place Crimp in the locations shown in the Packard Conne...

Page 8: ...hat the control orifice and spring are in the proper position in the control 2 Engage the pin on the control linkage in the mating hole in the link attached to the swashplate To ensure that linkage is engaged before adding mounting bolts simply place a finger under the electrical input connection and lightly lift If the control moves more than 3 8 inch the pin is not engaged Try again See the Cont...

Page 9: ...e Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 Phone 763 509 2084 Fax 763 559 0108 DEVICE REPAIR For devices in need of repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 EU...

Reviews: