background image

BLN-95-8995-4

Issued

: September 1996

DESCRIPTION

MCV111B

Electrical Displacement Control-PV

Series 90

.

.

FEATURES

• Servo  control  deadband  independent  of  signal  null

deadband:  offers  safety  combined  with  accurate  and

responsive control

• Resistance  to  the  environment:  standard  silicone  oil

filled torque motor, environmentally sealed first/second

stage interface, full environmental testing

The MCV111B Electrical Displacement Control (EDC) is a

two-stage electrohydraulic pump stroke control which uses

mechanical feedback to establish closed loop control of the

swashplate angle of Danfoss Series 90 Pumps.

The first stage, the MCV110 Pressure Control Pilot (PCP) is

a torque-motor actuated, double-nozzle flapper valve that

produces a differential output pressure proportional to the

applied  electrical  signal.  The  second  stage  uses  the

differential pressure to drive its unique spool arrangement

and port oil to the pump servo cylinders. The second-stage

spool  configuration  allows  a  null  deadband  (for  machine

safety)  in  the  pump’s  output  while  maintaining  optimum

dynamic response to control commands.

1. PUMP SIZE

MODEL CODE

PUMP SIZE

03

30 cc

05

42 or 55 cc

07

75 cc

10

100 cc

13

130 cc Pump S/N < 92 - 19

14

130 cc Pump S/N 

 92 -19

18/25

180 or 250 cc

BASE

DEVICE

PUMP

SIZE

PILOT STYLE

2. PILOT

MODEL CODE

PILOT STYLE

02

MS Connector

04

Packard Connector

ORDERING INFORMATION

The MCV111B Electrical Displacement Control is ordered by

specifying the pump size and pilot type as shown in Table A.

Consult Danfoss, Minneapolis, MN, with further

questions.

• Minimum long term null shift

• Dual coil torque motor can be used to sum two command

sources

TABLE  A.  INFORMATION  NECESSARY  TO  SPECIFY

THE EDC.

EDCs ordered separate from the pump must have mounting

kits ordered separately:

30/55 cc PUMP KIT (KIT NUMBER KK11655)

Comprised  of  one  K07652  gasket  and  six  9007314-

0611 bolts

75/100/130 cc PUMP KIT (KIT NUMBER KK11675)

Comprised  of  one  K07653  gasket  and  six  9007314-

0611 bolts

42 cc PUMP KIT (KIT NUMBER KK11642)

Comprised of one K07652 gasket, six 9007314-0611

bolts and one K09123 washer

180/250 cc PUMP KIT (KIT NUMBER KK11618)

Comprised of one K07653 gasket, six 9007314-0611

bolts and one K09123 washer

MCV111B

XX

XX

© Danfoss, 2013-09 

BLN-95-8995-4 

1

Summary of Contents for MCV111B Series

Page 1: ...the pump s output while maintaining optimum dynamic response to control commands 1 PUMP SIZE MODEL CODE PUMP SIZE 03 30 cc 05 42 or 55 cc 07 75 cc 10 100 cc 13 130 cc Pump S N 92 19 14 130 cc Pump S N 92 19 18 25 180 or 250 cc BASE DEVICE PUMP SIZE PILOT STYLE 2 PILOT MODEL CODE PILOT STYLE 02 MS Connector 04 Packard Connector ORDERING INFORMATION The MCV111B Electrical Displacement Control is ord...

Page 2: ...ESSURE Typically 300 400 psi above case pressure RATINGS SCALE FACTOR 1 15 psi mA single coil 2 3 psi mA coils in series 1 15 psi mA coils in parallel TEMPERATURE The valve will meet all specifications over the range of 21 to 82 C 70 to 180 F TECHNICAL DATA ELECTRICAL CHARACTERISTICS Voltage to Terminal One of Dual Coils Dual Coils in Parallel Dual Coils in Series Input Produces Shaft Flow Out Rot...

Page 3: ...ERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 MS CONNECTOR OPTION PACKARD WEATHER PACK CONNECTOR OPTION DIMENSIONS 42 cc AND 55 cc PUMP EDC LOCK NUT MANUAL OPERATOR SAE SERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 CONTROL LINKAGE 10 4 0 41 22 4 0 88 27 94 1 10 52 83 2 08 203 2 8 00 8 6 REF 0 34 7 11 0 28 NEUTRAL ADJUST 7 14 DIA 6 PLACES 0 281 DIA 122 99 4 84 89 41 3 52 55 37 2 18 36 07 1 42 31...

Page 4: ...al pressure drop when the system is at null Between the nozzle and the orifice on each side is a control port As the torque motor shifts the flapper away from one nozzle toward the other a differential control pressure results the high side being the one nearer the flapper Fluid pressure rises on this side and moves the flapper back towards null When the torque output from the motor equals the tor...

Page 5: ... or if the pilot output pressure goes to case pressure Mechanical feedback must be present FREQUENCY RESPONSE EXCEPT FOR 130 cc PUMPS 2 Hz minimum with 052 pressure limiter orifices 3 Hz minimum without pressure limiter orifices with pressure limiters inoperative Under 500 1000 psi load at 90 phase lag with 10 mA signal at 45 mA offset TIME RESPONSE EXCEPT FOR 130 CC PUMPS 1 0 seconds 0 to full st...

Page 6: ...nnector order part number K08106 The mating Packard ENVIRONMENTAL HUMIDITY After being placed in a controlled atmosphere of 95 humidity at 49 C 120 F for 10 days the EDC will perform within specification limits Meets MIL STD 810B WIRING connector is a bag assembly part number K03384 comprised of 1 4 14 16 gauge sleeves 2 4 18 20 gauge sleeves 3 1 plastic housing 4 4 green cable seals accept 2 2 2 ...

Page 7: ...nsulation should just protrude beyond the seal 4 Select the larger of the two sets of pins as measured at Dimension A see the Dimension A drawing if using 14 16 gauge wire Choose the smaller if using 18 20 gauge Place the wire into the socket so that the seal edge is pushed through and extends slightly beyond the circular tabs that hold it in place Crimp in the locations shown in the Packard Conne...

Page 8: ...hat the control orifice and spring are in the proper position in the control 2 Engage the pin on the control linkage in the mating hole in the link attached to the swashplate To ensure that linkage is engaged before adding mounting bolts simply place a finger under the electrical input connection and lightly lift If the control moves more than 3 8 inch the pin is not engaged Try again See the Cont...

Page 9: ...e Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 Phone 763 509 2084 Fax 763 559 0108 DEVICE REPAIR For devices in need of repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 EU...