Danfoss MCD 500 Series Instructions Download Page 3

MCD500 PCB Replacement 

 

MCD 500 PCB Replacement - Instructions 

 MI.17.F1.02 

VLT

®

 is a registered Danfoss trademark 

Page 3/5 

3.  Model MCD5-0245C  

Remove the top cover and terminal blocks from 
the starter. Undo the 4 x Torx screws holding the 
top plastic.  

 

Tilt the top plastic to the right to expose the wiring 
looms. Label each SCR firing loom with the number 
of the corresponding phase terminal on the main 
control PCB, then unplug the SCR firing looms 

Unplug the thermistor, fan and CT wires from the 
LCP and main control PCB and set the top plastic 
aside. 

 

Undo the 4 x Torx screws from the model PCB 
support bracket and set aside. 

Unplug the header connector from the main 
control board and set aside. 

 

Remove 7 x Torx screws. Replace the LCP and main 
control PCB assembly. Replace the 7 x Torx screws 

Replace the header connector. 

Replace the model board, check that the header 
connector pins line up with the main control PCB 

below. 