Specifications

Output current

4 – 20 mA

Supply voltage

10 – 28 V

Adjustable Type (MBS47x1-xxxx-1xxxx, MBS47x1-xxxx-7xxxx):

Ambient temperature

T4

-40 – 100 °C

Media temperature

T4

-40 – 125 °C

Pressure specification

Measuring range

bar

0 – 1 0 – 1.6 0 – 2.5 0 – 4

0 – 6 0 – 10 0 – 16 0 – 25 0 – 40 0 – 60 0 – 100 0 – 160 0 – 250 0 – 400 0 – 600

Overload (Static)

bar

6

12

24

24

60

60

150

150

300

360

600

1200

1500

1500

1500

Burst pressure

bar

100

100

100

100

100

100

150

150

400

800

1200

1200

2000

2000

2000

Plug Type, non-adjustable (MBS42x1-xxxx-1xxxx;; MBS42x1-xxxx-7xxxx):

Ambient temperature

T4

-40 – 100 °C

T5

-40 – 75 °C

T6

-40 – 50 °C

Media temperature

T4

-40 – 125 °C

T5

-40 – 95 °C

T6

-40 – 50 °C

Fixed Cable Types, non-adjustable, MBS 42x1-xxxx-Yxxxx (Y =3, 4, 5, C, D are indicative cable lengths, max. 12 m)

3, 4, 5 PVC cable

C,D. ETFE cable

Ambient temperature (fixed installations)

T4

-40 – 80 °C

-40 – 95 °C

T5

-40 – 75 °C

-40 – 75 °C

T6

-40 – 50 °C

-40 – 50 °C

Ambient temperature (cables flexed during 

installation or operation)

T4

-5 – 70 °C

-5 – 70 °C

T5

-5 – 70 °C

-5 – 70 °C

T6

-5 – 50 °C

-5 – 50 °C

Media temperature

T4

-40 – 125 °C

-40 – 125 °C

T5

-40 – 95 °C

-40 – 95 °C

T6

-40 – 50 °C

-40 – 50 °C

Electrical

Safety specifications

Max. supply voltage

Ui

28 V

Max. Input current

Ii

100 mA

Max. Input power

Pi

0.7 W

Internal capacity

Ci

50 nF

Internal inductance

Li

8 μH

Reviews: