IC.PI.P20.G7.53 

http://ic.danfoss.com/

 

®Danfoss A/S , DE-BD, 07-2009

060R9328

060R9328

Instructions

60 Nm

Zero adjustment

Span adjustment

0 – 1  

  0 – 10 bar

-5  

 +20% FS

-5  

 +5% FS

0 – 16  

 0 – 40 bar

-5  

 +10% FS

0 – 60  

 0 – 600 bar

-5  

 +2.5% FS

 

 

 

 

 

 

 

 

 

Australian  approvals:
According to N1297

American and Canadian approvals: 
1. Temperature indicating equipment acc. to UL 873, file no E31024 and Process control equipment acc. to CSA 

std. C22.2 no 142-M1987 

2. Class I, Div. 2, Group A, B, C and D acc. to UL 1604, file no E227388 and Non-incendive electrical equipment for 

use in Class I, Div. 2, Group A, B, C and D acc. CSA std. no C22.2 no 213-M1987 
Must be powered by a Class 2 power supply when used in Haz. Loc. Class I, Div. 2, Group A, B, C and D.
MWP 600 bar/ 8700 psi.

Type

MBS 32/ 33, MBS 32R, MBS 4050, MBS 33M 
MBS 2000, MBS 2050, MBS 3000/ 3050 
MBS 3100/ 3150, MBS 4010/ 4510

MBS 2100/ 2150 
MBS 2200/ 2250 
MBS 3200/ 3250
MBS 3300/3350

Max. ambient temperature

85º C/ 185º F

125º C/ 257º F

Temperature code

T4

T3B

MBS 4510

MBS 4510

MBS 3300
MBS 3350