Mounting flange - G-factors for sample applications
Application
Continuous (vibratory)
acceleration (G
c
)
Maximum (shock) acceleration
(G
s
)
Skid steer loader
6
10
Trencher
(rubber tires)
6
8
Asphalt paver
6
6
Windrower
6
5
Aerial lift
6
4
Turf care vehicle
6
4
Vibratory roller
6
10
Applications experiencing extreme resonant vibrations may require additional pump support. Refer to
on page 10 for information concerning mounting flange loads.
Technical Information
LPV Axial Piston Pumps
Technical specifications
22 |
©
Danfoss | September 2017
520L0954 | BC00000044en-US0102