Quick Guide 

living connect® Z, Electronic Radiator Thermostat

2

VQIDC202                       © Danfoss                       12/2014

Temperature control and adjustment

The temperature is usually con-trolled via 

the controller, but may be changed at any 

time using the thermostat’s buttons.

If this is done, the thermostat sends a 

message to the controller, which then 

syncronises other thermostats in the 

same room.

18

19

20

21

26

25

24

23

Press

 

 

to change

the temperature.

Excluding the device from the network

•  Activate “Exclusion” on the Z-Wave controller.

•  Quickly press and release 

 on 

living connect® Z

.

•  Observe both controller and 

living connect® Z

 for status of the 

process.

Re-installation mode

If the thermostat has been removed from 

the radiator and needs to be reinstalled 

(after being used), it is necessary to activate 

installation mode to prevent damage to the 

thermostat.
To enter installation mode:

•  Press 

 until 

M

 is displayed. 

•  Press 

 to withdraw the spindle. 

M

 

fl

ashes.

•  Reinstall the thermostat on the valve. 

•  Press 

 for approx. 3 seconds to 

fi

x the thermostat.

If the thermostat is moved to another room, make sure to make 

the necessary changes in the controller.

Factory reset

Remove the battery cover and take out one battery. Press and 

hold 

 for approx. 5 seconds, while re-inserting the battery. 

living connect® Z

 is now factory reset and in mounting mode.

Wake up

A controller can only communicate with 

living connect® Z

, when 

the device is awake. The intervals when the thermostat is awake 

can be set using the “wake up command class”.

Press 

 to manually wake up the device. It will stay awake for 10 

seconds and send out a node info.

Z-wave info

Device type

Slave

SDK

4.55

Software version

1.01

ProduktID

4

Explorer frames

YES

Implemented Z-Wave device classes

Z-Wave

Device Classes

Device Class

Implemented

Generic device

GENERIC_TYPE_THERMOSTAT

Speci

fi

c device

SPECIFIC_TYPE_SETPOINT_THERMOSTAT

Supported and controlled Z-Wave command classes

Z-Wave Command

Classes Supported

Description

COMMAND_CLASS_BATTERY

Get current battery status of 

living connect®

.

COMMAND_CLASS_CLIMATE_

CONTROL_SCHEDULE

Control a temperature o

ff

set 

to the thermostat setpoint of 

living connect®

. The tem-

perature o

ff

set is de

fi

ned 

by schedules and schedule 

overrides.

COMMAND_CLASS_CLOCK

Set or get the current 

living 

connect®

 clock.

COMMAND_CLASS_

MANUFACTURER_SPECIFIC

Get manufacturer ID of 

system.

COMMAND_CLASS_MULTI_

CMD

A special Z-Wave command 

used by 

living connect®

 to en-

capsulate multiple commands 

in one command and thereby 

conserve battery life.

COMMAND_CLASS_

PROTECTION

Set or get 

living connect®

 local 

protection mode. Possible lo-

cal protection values are:

0 = no protection

2 = fully locked (tamperproof)

COMMAND_CLASS_

THERMOSTAT_SETPOINT

Set or get current thermostat 

setpoint of 

living connect®

Heating setpoint is the only 

supported setpoint type.

COMMAND_CLASS_VERSION

Get version of product and 

command classes.

COMMAND_CLASS_WAKE_UP

A special Z-Wave command 

used by 

living connect®

 to 

synchronize communication 

with its controller.