7
Installation Guide
3�1
Configuration
See Step-by-Step guide in Danfoss Link™ CC instruction
manual.
Green LED ON
Standby
Red LED ON
Heating
Green LED fast flash
Inclusion or link test
Red LED short flash
Inclusion not OK, goes to not
included.
Linktest not OK, goes to
missing link
RED LED slow flash
Sensor failure
4
Factory reset
Turn off power on the safety switch on the front. Hold the
install button in while pushing ON the safety switch and
keep the install button pressed until the LED gives a red
flash (approx. 5 sec.)
5
Technical specifications
Operation voltage
220-240 V~ 50/60 Hz~
Standby power
consumption
Max. 1 W
Danfoss Link™ FT