13
VIIFR102 © Danfoss 03/2014
Installation manual
Danfoss Link™ HP kit
Connection to Danfoss Link™ CC
C
Before connecting to a power outlet, make sure that the electrical installation has been carried out
correctly and that there is no risk of injury or damage.
Note!
The heat pump must be added to the network as a
service unit
. For more information about connecting to
networks see the accompanying Danfoss Link™ CC Installation Manual.
Add any dedicated repeaters (CF-RU) BEFORE adding the heat pump to the wireless network.
Note!
During installation, the distance between Danfoss Link™ CC and DCM03 must not exceed 1.5 metres.
Rooms and units
?
1
Service functions
Add service unit
?
2
Rooms and units
?
Start registration
Add service unit
3
Click here to add the DCM03 module to
Danfoss Link ™CC.
•
Start the heat pump
•
Remove the front panel from the Danfoss Link™ CC by carefully
pulling it off. Pull near the edges of the panel.
•
Press the Setup button for three seconds to open the service
area
.
Connect other service and room units, e.g. HC floor heating and living connect radiator thermostats. Start
with the service units. For more information about connecting other units, see the accompanying Danfoss
Link ™ CC installation instructions.
Connecting other units to Danfoss Link™ CC, wireless connection