![Danfoss Ikompact User Manual Download Page 10](http://html1.mh-extra.com/html/danfoss/ikompact/ikompact_user-manual_3464615010.webp)
Ikompact troubleshooting guide
The transmitter has status monitoring LEDs which help to identify errors and warnings. The common
signals are shown in the table below.
Color and frequency
Pulse frequency
Description
Action
Blue | fast pulses
System is starting; establishing connection with radio
and EEPROM
Wait
Blue | continuous
System is in stand-by mode, waiting for user's action
Press START to enter operation
mode
Green | fast pulses
Attempting to link with receiver and waiting for
response
Wait
Green | continuous
Working
Operate
Green | slow pulses
Latency; no action has been taken for some time
Press START to return to operation
mode
Red | slow pulses
EEPROM module missing or corrupt
Check EEPROM and reprogram if
necessary
Red | double pulses
Radio communication error
Replace transmitter
Red | continuous
Hardware failure
Replace transmitter
Orange | slow pulses
Critical battery signal
Replace or charge batteries
Orange | double pulses
Activated maneuver
Release maneuver
User Manual
Ikompact transmitter
Maintenance
10 |
©
Danfoss | February 2019
BC293071182708en-000101