background image

FCC rules

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules.

Changes or modifications not expressly approved by the manufacturer can void the user's authority to
operate the equipment.

To comply with FCC RF exposure compliance requirements, this device and its antenna must not be
collocated with, or operating in conjunction with, any other antenna or transmitter, may not cause
harmful interference, and must accept any interference received, including interference that may cause
undesired operation.

The limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy, and if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.

W

Warning

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes:

1. l'appareil ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est

susceptible d'en compromettre le fonctionnement.

IK2 General Safety

The following safety instructions must be read carefully to install and use the product properly, and to

keep it in perfect working condition, and to reduce the risk of misuse.

Strictly adhere to the installation instructions contained in this document.

Make sure that professional and competent personnel carry out the installation.

Ensure that all site and prevailing safety regulations are fully respected.

Make sure that this document is permanently available to the operator and maintenance personnel.

Keep the transmitter out of reach of non-authorized personnel.

Remove the transmission key when the set is not in use.

Check each working day the STOP button and other safety measures. When in doubt, press the STOP
button.

Whenever several sets have been installed, make sure the transmitter is the right one. Identify the
machine controlled on the label for this purpose on the transmitter or by using the display (in case it
has one).

Service the equipment periodically.

When carrying out repairs, use spare parts supplied by Danfoss only.

W

Warning

Potential damage to the operator or the product. Do not use this product on machines in potentially
explosive atmospheres unless the model is ATEX/RATEX certified to work in such conditions.

User Manual

Remote Control IK2 Transmitters

Safety instructions

 

4 | 

©

 Danfoss | May 2021

BC290862531428en-000201

Summary of Contents for IK2

Page 1: ...User Manual Remote Controls IK2 Transmitters www danfoss com...

Page 2: ...revisions Date Changed Rev May 2021 Added trouble shooting and start up information for TR2400 0201 December 2018 Rebranded to Danfoss 0101 User Manual Remote Control IK2 Transmitters 2 Danfoss May 20...

Page 3: ...description 9 Maintenance Maintenance tips 10 Troubleshooting 400 900 MHz 10 Troubleshooting 2 4GHz 10 Charger and battery Charger and battery 12 BC70K and BT11K specifications 12 BC70K Battery Charg...

Page 4: ...llage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement IK2 General Safety The following saf...

Page 5: ...s press STOP before plugging in tether cable if applicable Remove the Tether connection on the transmitter First if applicable Do not operate product when visibility is limited Make sure product is co...

Page 6: ...1 2 3 5 8 9 10 1 Label for crane identification 2 LED 3 Maneuver elements 4 Multi key or Key START Button 5 STOP button 6 Optional range limiter 7 External and extractable EEPROM module 8 Battery 9 M...

Page 7: ...er has LCD it displays the identification of the machine and battery level only if it has been pre programmed crane xx1 LED pulse Display option 4 Press the start button The green LED will now light t...

Page 8: ...blue If the transmitter includes a Display it will display the identification of the machine as well as the battery level if it has been pre programmed 4 Press the START button and wait for the statu...

Page 9: ...switches Removable EEPROM External Battery model BT11K Battery life 8 hours Response Time 100ms Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to...

Page 10: ...ties The most common signals are contained in the table below Color and frequency Pulse frequency Description Action Green continuous Working Operate Green slow pulses Latency no action has been taken...

Page 11: ...n mode Red slow pulses EEPROM module missing or corrupt Check EEPROM and reprogram if necessary Red double pulses Radio error radio communications error Replace transmitter Red continuous General hard...

Page 12: ...perature 0 C to 45 C Discharge temperature 20 C to 60 C Charging mode Fast 2 5 h and intelligent Weight 23 g BC70K Battery Charger Set up The battery charger has two charging compartments that can sim...

Page 13: ...ies and battery charger follow these recommendations Do not recharge the battery until it is completely flat as shown with red LED slow pulse on the transmitter Always charge the batteries at temperat...

Page 14: ...BC70K Battery Charger Dimensions Dimensions mm 97 15 103 31 30 10 23 50 127 90 2 57 User Manual Remote Control IK2 Transmitters Charger and battery 14 Danfoss May 2021 BC290862531428en 000201...

Page 15: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...