background image

 

 

 

Instruction Manual 

5 | 

P a g e

 

 

 
 

6.

 

Error Codes 
 
 
 

The error codes are depicted by a number of flashes by the error light in a sequence every 
four seconds. 
 
 
 

Code 

Reason / Solution 

1 Flash 

Low Voltage

     

-

 

Please check the source voltage to ensure it is above 
the cut out. Try lowering the voltage cut out setting to 
LOW. 

-

 

The vehicle cabling may be inadequate/unsuitable, 
please refer to cable specifications table for correct 
cable thickness. 

2 Flashes   

Fan or compressor running issue 

-

 

Fan is drawing too many Amps (Over 1 Amp)    – 
Replace Fan.   

-

 

The compressor is drawing too many amps (Over 12 
Amps) 

-

 

Possible Electronic Box or compressor fault – contact 
Evakool or Service Agent 

3 Flashes 

The compressor speed is too low 

-

 

Reduce products / items inside unit 

-

 

Move unit to a lower ambient temperature 

-

 

Clean vents / ensure clear air flow over compressor 

4 Flashes 

Ambient Temperature too high 

-

 

Clean vents / ensure clear air flow

 

-

 

Fan Fault – Replace fan

 

 

 

 

Reviews: