![Danfoss ECtemp 530 Installation Manual Download Page 11](http://html1.mh-extra.com/html/danfoss/ectemp-530/ectemp-530_installation-manual_3562959011.webp)
Danfoss ECtemp 530
11
Installation Guide
• Floor manufactures often specify the max tempera-
ture on the top surface of the floor (usually 27-28 °C).
• Always use a floor sensor to control floor heating.
Without a floor sensor, the temperature control may
be less accurate and you risk overheating the floor.
Thermal
resist-
ance
[m²K/W]
Examples of
flooring
Details
Approximate
setting for
25 °C on top
surface of
floor
0,05
8 mm HDF based
laminate
> 800
kg/m³
28 °C
0,10
14 mm beech
parquet
650 -
800 kg/m³
31 °C
0,13
22 mm solid oak
plank
> 800
kg/m³
32 °C
< 0,17
Max. carpet thick-
ness suitable for
floor heating
acc. to
EN/IEC
1307
34 °C
0,18
22 mm solid fir
planks
450 - 650
kg/m³
35 °C