![Danfoss DEVIreg 850 Installation And User Manual Download Page 14](http://html1.mh-extra.com/html/danfoss/devireg-850/devireg-850_installation-and-user-manual_3426094014.webp)
DEVIreg™ 850 ground and roof sensors
Installation and user manual
14
4
Appendix А
4 .1
Sensor cable extension
Ground system
Number of sensors:
1 or 2
3
4
Cable type
1 mm2
1.5 mm2
2.5 mm2
4 mm2
Max length (m)
300
450
750
1200
Max. length (m)
150
225
380
600
Max length (m)
80
120
200
310
Roof system
Number of sensors:
1
2
3
4
Cable type
1 mm2
1.5 mm2
2.5 mm2
4 mm2
Max length (m)
400
600
1000
1600
Max length (m)
100
150
250
400
Max length (m)
130
200
330
525
Max length (m)
75
110
190
300