background image

DEVIreg™ 233

Installation Guide

4

Dimensions

71x 44 x 31mm 
(in-wall depth: 20mm)

Weight

77 g

The product complies with the EN/IEC Standard “Automatic 
electrical controls for household and similar use”:

•  EN/IEC 60730-1 (general)
•  EN/IEC 60730-2-9 (thermostat)

1�2 

Safety Instructions

Make sure the mains supply to the thermostat is turned off 
before installation.

IMPORTANT:

 When the thermostat is used to control a 

floor heating element in connection with a wooden floor or 
similar material, always use a floor sensor and never set the 
maximum floor temperature to more than 35°C.

Please also note the following: 

•  The installation of the thermostat must be done by 

an authorized and qualified installer according to 
local regulations.

•  The thermostat must be connected to a power sup-

ply via an all-pole disconnection switch.

•  The sensor is to be considered as live voltage. Have 

this in mind if the sensor must be extended.

•  Always connect the thermostat to continuous 

power supply.

Summary of Contents for DEVIreg 233

Page 1: ...www DEVI com Installation Guide DEVIreg 233 Electronic Thermostat...

Page 2: ...box from the LK FUGA series The thermostat is provided with a 1 pole switch and a floor sensor to measure and control the desired floor temperature It can also be used with an external room sensor Th...

Page 3: ...NTC 15 kOhm at 25 C Sensing values 0 C 25 C 50 C 42 kOhm 15 kOhm 6 kOhm Hysteresis 0 4 C 0 8 C Ambient temperature 0 C to 40 C Frost protection temperature 5 C Temperature range 0 5 C to 45 C Cable sp...

Page 4: ...is used to control a floor heating element in connection with a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Please also no...

Page 5: ...et due to the risk of condensed water and water splash Note A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden f...

Page 6: ...r in the hole on top of the thermostat and lifting the cover outwards Loosen the two screws and carefully detach the unit 2 Connect the thermostat according to the connection diagram Max Load 13 1 A M...

Page 7: ...to fasten the thermostat Press the front cover back in place 4 Turn on the power supply 3 Settings Please be aware of the following The floor temperature is measured where the sen sor is placed The te...

Page 8: ...Ireg 233 Installation Guide 8 How to change the minimum and maximum floor temperatures 1 Remove the front cover 2 Move the adjustment sledg es to the desired positions 3 Put the front cover back in pl...

Page 9: ...ance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must be filled in stamp...

Page 10: ...on Guide 10 WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date S...

Page 11: ...DEVIreg 233 Produced by Danfoss 03 2023 08091349 AQ069786451637en 010204 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark 5 Disposal Instruction...

Page 12: ...1020 DK Electronic thermostat 220 240V 50 60Hz 5 C to 45 C 13A 2990W 230V IP41 Product documentation 233 6 5 4 3 2 1 DK EL 7224215043 Designed in Denmark for Danfoss A S 08095090 7 0 3 4 6 6 2 0 8 9 8...