Setting the Max Sensor value lets the system detect several error conditions, such as a loss of a sensor
during operation or accidentally assigning two sensors the same machine position (PLID).
Pairing CWH1000 to WMS1000 and a machine position
WMSS1000 position on the machine
To assign a WMSS1000 Multi-Sonic Sensor to a given position on a machine, the sensor must be assigned
a PLID (Programmable Location ID) number.
For example, on the paver machine in the figure below, the front left will be PLID 1, the middle left will be
PLID 2, and back left will be PLID 3. To continue on the other side, the front right will be PLID 4, the
middle right will be PLID 5, and the back right will be PLID 6.
Paver PLID (WMSS1000 position)
Once the machine positions are numbered, you can permanently pair the WMS1000 to a machine
position with the Pair Sensor Command that is detailed in the programmers manual.
Once the sensor is paired, the PLID information is then programmed onto the machine mount such that
any future sensors mounted in that position can run without setting up the system again.
Technical Information
CWH1000 Wireless Hub
CWH1000 wireless communications
14
L1321661 • Rev AA • Mar 2014