background image

CET2000B-RF + RX1-S + CS2

Wireless Electronic Hot Water Cylinder Thermostat

Installation Guide

Danfoss Heating

Summary of Contents for CET2000B-RF

Page 1: ...CET2000B RF RX1 S CS2 Wireless Electronic Hot Water Cylinder Thermostat Installation Guide Danfoss Heating...

Page 2: ...n this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved Hearby Danfoss A S declares that the radio equipment type CE...

Page 3: ...MHz 1mW ERP IP Rating IP20 IP40 Control On Off Operating mode Domestic Hot Water Heating Construction EN 60730 2 9 EN 60730 1 Control pollution situation Degree 2 Rated impulse voltage 2 5kV Ball pres...

Page 4: ...be taken to remove any insulation material from the cylinder and to ensure that the copper surface of the cylinder is clean See diagram opposite for details This product should only be installed by a...

Page 5: ...part of the sensor in contact with the cylinder and clamp the sensor to the cylinder wall A spacer piece is provided for use with cylinders that have thick insulation see page 6 4 Mount the thermostat...

Page 6: ...ET2000B RF 6 1 2 cylinder height For insulation thicker than 25mm and up to 55mm thick use the extra cover supplied as a spacer to ensure that the sensor is held in firm contact with the cylinder wall...

Page 7: ...Danfoss Heating 7 Sensor Wiring CS2 sensor 1 2 3 CET2000B RF Cable specification minimum cross section 0 5mm2...

Page 8: ...X1 S Receiver unit ELECTRONICS N L N L 2 3 4 COM ON OFF 230Vac 1 Please Note This product should only be installed by a qualified electrician or competent heating installer and must be in accordance w...

Page 9: ...Danfoss Heating 9 Mounting CET2000B RF...

Page 10: ...osition Valve ELECTRONICS N L 1 2 3 ELECTRONICS N L 2 HTG OFF 3 HW ON 4 HTG ON 230Vac 1 HW OFF RET1000MS Room Thermostat RX1 S Receiver paired to CET2000B RF FP715 Programmer 3 Port Mid Position Valve...

Page 11: ...ELECTRONICS N L 2 HTG OFF 3 HW ON 4 HTG ON 230Vac 1 HW OFF RX1 S Receiver paired to CET2000B RF FP715 Programmer Hot Water 2 Port Valve FP715 Programmer Pump Heating 2 Port Valve blue brown orange gre...

Page 12: ...NICS N L 1 2 3 ELECTRONICS N L 2 HTG OFF 3 HW ON 4 HTG ON 230Vac 1 HW OFF RET1000MS Room Thermostat RX1 S Receiver paired to CET2000B RF FP715 Programmer Hot Water 2 Port Valve FP715 Programmer Pump H...

Page 13: ...CTRONICS N L 1 2 3 ELECTRONICS N L 2 HTG OFF 3 HW ON 4 HTG ON 230Vac 1 HW OFF RX1 S Receiver paired to CET2000B RF FP715 Programmer 3 Port Mid Position Valve FP715 Programmer Pump blue brown white ora...

Page 14: ...KEYS LOCKED To avoid unwanted tampering of the required hot water tem perature the CET2000B RF includes a key lock feature which disables the and V buttons First set the required hot water temperatur...

Page 15: ...wired in accordance with instructions on page 8 Step 2 CET2000B RF Insert 2xAA alkaline batteries If the CET2000B RF is not already paired to the RX1 S it will enter it s learning mode shown by the f...

Page 16: ...Part No 44101v01 04 15 Danfoss Ltd Ampthill Road Bedford MK42 9ER Tel 01234 364621 Fax 01234 219705 Email ukheating danfoss com Website www heating danfoss co uk VIAGD102...