![Danfoss APP 11-13 Instruction Manual Download Page 5](http://html1.mh-extra.com/html/danfoss/app-11-13/app-11-13_instruction-manual_3459457005.webp)
Instruction
Changing pistons APP 11-13 and APP 16-22
5
180R9227 / 521B1194 / DKCFN.PI.013.O1.02 / 03.2012
2. Assembling
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
All parts must be absolute clean before
mounting.
1.
Carefully push the retainer plate in place.
2.
Ensure that the retainer plate is oriented
correctly with its slant surfaces pointing
downwards.
3.
Insert all the pistons randomly.
Note: Tilt the retainer plate for easy insert of
the swash plate. Place pin in the housing.