Service guide
|
Disassembling and Assembling, APP 1.5-3.5
© Danfoss | DCS (im) | 2017.08
2 | 180R9091 | DKCFN.PI.013.EF5.02 | 521B0741
Table of Contents
NOTE: If the pump is disassembled within the warranty period, the pump is no longer covered
by the warranty.
Introduction
This document covers the instructions for
disassembling and assembling the axial piston
pump APP 1.5-3.5
Tools needed:
•
Shaft seal tool (code no. 180B4148)
•
Press bush
•
Allen key 5mm
•
2 Screwdrivers
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
To understand the pump design better, please
see exploded view on last page.
WARNING: Do not reuse disassembled O-ring
or shaft seal as they might be damaged.
Contents
Introduction ................................................................................................................................................................................2
1. Disassembling and assembling the pump .............................................................................................................3
2. Change of shaft seal .......................................................................................................................................................7
3. Exploded views.............................................................................................................................................................. 10
3.1 APP 1.5-2.5 ...................................................................................................................................................................... 10
3.2 APP 3.0-3.5 ...................................................................................................................................................................... 11