Function
Values
R-W
Code
1
2
3
4
5
6
7
8
9
Min. value Max. value Fact. value
Dewpoint min limit
1-2
o86
*
*
*
*
*
*
*
*
*
-10.0 °C
o87
8.0 °C
Dewpoint max limit
1-2
o87
*
*
*
*
*
*
*
*
*
o86
50.0 °C
17.0 °C
Rail heat min ON cycle
1-2
o88
*
*
*
*
*
*
*
*
*
0 %
100 %
30%
Door restart inj. delay
1-2
o89
*
*
*
*
*
*
*
*
*
0 min
240 min
30 min
Fan at forced closing
0=OFF, 1=ON, 2=OFF and
suppress defrost, 3=ON
and suppress defrost
1-2
o90
*
*
*
*
*
*
*
*
*
0
3
1
Light at Main switch OFF
0=OFF, 1=Normal ctrl.
1-2
o98
*
*
*
*
0
1
0
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
Control
Table 20: Control
Function
Values
R-W
Code
1
2
3
4
5
6
7
8
9
Min. value Max. value Fact. value
Alarm relay priority
0=Not used, 1=High Prior-
ity, 2=Medium priority,
3=All
1-2
P41
*
*
*
*
0
3
2
Blinds max open time
1-2
P60
*
*
0 min
60 min
5 min
Fan stop at blinds closing
1-2
P65
*
*
*
*
0 s
300 s
0 s
Rail heat PWM - Period
time
1-2
P82
*
*
*
*
*
*
*
*
*
4 s
60 s
10 s
Refrigerant factor K1
1-3
(1)
P83
*
*
*
*
*
-999
999
300
Refrigerant factor K2
P84
*
*
*
*
*
-999
999
300
Refrigerant factor K3
P85
*
*
*
*
*
-999
999
300
Max superheat liquid ctrl.
1-2
P86
*
*
*
*
*
P87
20.0 °C
3.0 °C
Min superheat liquid ctrl
1-2
P87
*
*
*
*
*
0.0 °C
P86
1.0 °C
Access code 1
1-1
P88
*
*
*
*
*
*
*
*
*
0
999
0
Display keyboard lock
0=None, 1=Local, 2=Net-
work
1-2
P89
*
*
*
*
*
*
*
*
*
0
2
0
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
DO config and manual
Table 21: DO config and manual
Function
Values
R-W
Code
1
2
3
4
5
6
7
8
9
Min. value Max. value Fact. value
DO2 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
1-3
(1)
q02
*
*
0
10
6
DO3 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
q03
*
*
0
10
8
DO4 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
q04
*
*
0
10
9
AO1 Configuration
0=None, 1=Rail heat PWM 1-3
q09
*
*
*
*
*
*
*
*
*
0
1
0
EEV override A
1-2
(2)
q11
*
*
*
*
*
0 %
100 %
0%
Compressor 1 - override
0=MAN OFF, 1=MAN ON
q12
*
*
*
*
*
*
0
1
0
Fan - override
0=MAN OFF, 1=MAN ON
q13
*
*
*
*
*
*
*
*
*
0
1
0
Defrost A - override
0=MAN OFF, 1=MAN ON
q14
*
*
*
*
*
*
*
*
*
0
1
0
Rail heat - override
0=MAN OFF, 1=MAN ON
q15
*
*
*
*
0
1
0
Alarm relay - override
0=MAN OFF, 1=MAN ON
q16
*
*
*
*
0
1
0
Light - override
0=MAN OFF, 1=MAN ON
q17
*
*
*
*
0
1
0
Compressor 2 - override
0=MAN OFF, 1=MAN ON
q19
*
*
0
1
0
© Danfoss | Climate Solutions | 2022.08
BC365212986197en-000201 | 41