Compact - continued
R-W Code 1 2 3
4
5 6 7
8
9
Min.
Max.
Fac.
Actual
Replace the controller's factory settings with the
present settings
3-3*
o67
1
1
1
1
1
1
1
1
1 0/Off
1/On
0/Off
Rail heat control
0=not used, 1=pulse control with timer function (o41
and o42), 2=pulse control with dew point function A
1-2
o85
1
1
1
1
1
1
1
1
1 0
2
0
Dew point value where the rail heat is minimum
1-2
o86
1
1
1
1
1
1
1
1
1 -10°C
"o87"
8
Dew point value where the rail heat is 100% on
1-2
o87
1
1
1
1
1
1
1
1
1 "o86"
50°C
17
Lowest permitted rail heat effect in %
1-2
o88
1
1
1
1
1
1
1
1
1 0 %
100 %
30
Time delay from "open door” until refrigeration is
started
1-2
o89
1
1
1
1
1
1
1
1
1 0 min.
240 min.
30
Fan operation at stopped cooling (forced closing):
0= Stopped (defrost allowed)
1= Running (defrost allowed)
2= Stopped (defrost not allowed)
3= Running (defrost not allowed)
1-2
o90
1
1
1
1
1
1
1
1
1 0
3
1
Light and night blinds defined:
0: Light is switched off and night blind is opened
when the main switch is off
1: Light and night blinds are independent of main
switch
1-2
o98
1
1
1
1 0
1
0
Configuration of alarm relay:
The alarm relay will be activated by an alarm in one or
more of the following priorities.
Setting:
0 = The relay is not activated by alarms
1 = Only high priority alarms
2 = High and medium priority alarms
3 = High, medium and low priority alarms
1-2
P41
1
1
1
1
1
1
1
1
1 0
3
2
Max. opening time of night blinds after a manual
override with DI activation.
1-2
P60
1
1 0 min.
60 min.
5
Stop time for fans while the night blinds roll down
1-2
P65
1
1 0 sec
300 sec
0
Cycle time for rail heat at PWM on AO1
1-2
P82
1
1
1
1
1
1
1
1
1 4 sec
60 sec
10
User defined refrigerant 3-digit Rfg. factor K1
1-3*
P83
1
1
1
1
1 -999
999
300
User defined refrigerant 3-digit Rfg. factor K2
1-3*
P84
1
1
1
1
1 -999
999
300
User defined refrigerant 3-digit Rfg. factor K3
1-3*
P85
1
1
1
1
1 -999
999
300
Max. limitation of the superheat reference when
regulated with liquid-filled evaporator
1-2
P86
1
1
1
1
1 "P87"
20°C
3
Min. limitation of the superheat reference when
regulated with liquid-filled evaporator
1-2
P87
1
1
1
1
1 0°C
"P86"
1
Access code 1 (simple access)
1-1
P88
1
1
1
1
1
1
1
1
1 0
999
0
Locking of setting display
0 = display is never locked
1 = display is locked after 15 minutes of inactivity.
Display must be unlocked by pressing up and down
button simultaneously for 3 seconds.
1-2
P89
1
1
1
1
1
1
1
1
1 0/Off
1/On
0/Off
Configuration of relay output DO2: 0=not used,
1=fan, 2=fan Eco, 3=defrost, 4=rail heat, 5=alarm,
6=light, 7=night blinds, 8=compressor, 9=compressor
2, 10=heating element
1-3*
q02
1
1 0
10
0
Configuration of relay output DO3: 0=not used,
1=fan, 2=fan Eco, 3=defrost, 4=rail heat, 5=alarm,
6=light, 7=night blinds, 8=compressor, 9=compressor
2, 10=heating element
1-3*
q03
1
1 0
10
0
Configuration of relay output DO4: 0=not used,
1=fan, 2=fan Eco, 3=defrost, 4=rail heat, 5=alarm,
6=light, 7=night blinds, 8=compressor, 9=compressor
2, 10=heating element
1-3*
q04
1
1 0
10
0
Configuration of analogue output AO1: 0=not used.
1=rail heat PWM
1-3*
q09
1
1
1
1
1
1
1
1
1 0
1
0
Manual control of output: AKV valve 0-100%
1-2** q11
1
1
1
1
1 0 %
100 %
0
Manual control of output: Compressor1/LLSV
1-2** q12
1
1
1
1
1
1 0/Off
1/On
0/Off
Manual control of output: Fan
1-2** q13
1
1
1
1
1
1
1
1
1 0/Off
1/On
0/Off
Manual control of output: Defrost
1-2** q14
1
1
1
1
1
1
1
1
1 0/Off
1/On
0/Off
Manual control of output: Rail heat
1-2** q15
1
1
1
1 0/Off
1/On
0/Off
Manual control of output: Alarm
1-2** q16
1
1
1
1 0/Off
1/On
0/Off
© Danfoss | DCS (vt) | 2019.10
AN300028324304en-000401 | 13