background image

8

Perform following steps for assembly of plug half (male) coupling in fixed plate:

A. Insert plug body in respective hole in movable plate such that shoulder of the plug body is rested

against plate surface.

B. Install Jam Nut on plug half from opposite end of plate and screw nut in clock-wise direction.

C. Hold Jam nut in position by using standard tool and inserting it in slots provided on Nut.

D. Using standard wrench, hold hex on end connection of coupling and rotate in clockwise direction

to apply torque as per above chart.

8.3

REPLACEMENT PART NUMBERS

Refer below table for ordering correct parts for replacement. Other end connections are also available upon request for
plug and socket coupling assemblies.

M u l t i F F P a r t n u m b e r

P l u g c o u p l i n g

S o c k e t c o u p l i n g

D u s t c a p s e a l

4MFC-10CUP15LS11

10FFPCUP12LS21

10FFS15LS21

4MFS21-10S11

4MFCE1-12CUP15L

12FFPCUP15LS21

12FFS15LS21

4MFS21-12

4MFC-12CUP15L

12FFPCUP15LS21

12FFS15LS21

4MFS21-12

4MFC-1015L

10FFP15LS21

10FFS15LS21

4MFS21-10

4MFCE1-1015L

10FFP15LS21

10FFS15LS21

4MFS21-10

6MFC-1015L

10FFP15LS21

10FFS15LS21

6MFS21-10

9.0

OPERATING

Figure 5. Operating multiplate coupling

As shown in figure 5, two plates of assembly play major role in operation of connection and disconnection. Fixed plate
with lever and cover, and movable plate. Movable plate has plug (male) half and fixed plate has socket (socket) half.

1. First step is to open cover/dust cap and clean plate surface from any dust/foreign particles.

Summary of Contents for 4MFC-10CUP15LS11

Page 1: ...Installation Guide Generalinstructions for Danfoss Hansen Multiplate coupling AN444376292349en 000101...

Page 2: ...TIONS 3 3 0 OPERATING CONDITIONS 3 4 0 DURABILITYAND LIFETIME 4 5 0 MAINTENANCE 4 6 0 PRODUCT DESCRIPTION 5 7 0 INSTALLATION 6 8 0 SERVICING 6 8 1 SOCKET HALFREPLACEMENT 6 8 2 PLUG HALF REPLACEMENT 7...

Page 3: ...s section covers general operating conditions to obtain long life of multiplate coupling without unpredicted failure It is advisable to use multi plate coupling under same operation conditions The all...

Page 4: ...2 months storage period for the purpose of monitoringand repairs Replacement with original parts will ensure correct functionality Clean your quick coupling system once a week or every 50 coupling dec...

Page 5: ...ion Briefly this system would have two pre assembled sub systems one comprising of male halves plugs and other one having equal number of female socket halves with centralized lockingmechanism These t...

Page 6: ...anfoss Multi FF can be easily serviced and replaced upon malfunction Following sections and figures illustrates step by step guide for replacing these components with use of standard tools 8 1 SOCKET...

Page 7: ...ise direction to apply torque as per below chart Coupling series Coupling size Coupling half Torque in N m FF ISO 16028 ISO 6 Socket 60 FF ISO 16028 ISO 10 Socket 60 FF ISO 16028 ISO 12 Socket 90 FF I...

Page 8: ...connections are also available upon request for plug and socket coupling assemblies MultiFF Part number Plug coupling Socket coupling Dust cap seal 4MFC 10CUP15LS11 10FFPCUP12LS21 10FFS15LS21 4MFS21...

Page 9: ...nk by switching to correct direction control valve position and attachment on equipment is grounded properly Disconnection of Multi FF coupling under pressure is not recommended 2 After ensuring step...

Page 10: ...ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable future for tomorrow To learn more please visit http www d...

Reviews: