Remove control
1. Using a 5 mm internal hex wrench, remove the 4 control screws (C300) that fasten the control
assembly to the endcap (J020).
2. Remove the control from endcap. Discard interface O-rings. (C200).
Remove control
C200
C300
P109056
Item
Wrench size
C300
5 mm internal hex
Displacement limiter
1. Remove the adjustment seal/nut (L030).
The L030 adjustment seal/nut serves as a locking seal/nut, preventing the L040 screw from backing
out.
2. Remove the adjustment screw (L040). Remove plug (L010) with a 1 1/4 in. wrench. Discard the O-ring
(L010A).
L030
L010
L010A
L040
P109057
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
8 |
©
Danfoss | April 2017
AX00000305en-US0101