2. Remove the endcap. Remove the servo piston (L020) and guide (L080). Use care; valve plate (B070)
may adhere to inside surface. Discard O-rings (B045, B046). Refer to Inspection chapter for more
information.
B046
J030
J020
P109040
B070
J050
B020
J020
P109039
B010
J051
3. Slide the rear tapered roller bearing cone (B020) from the bottom end of the shaft. The bearing cup
(B010) may remain within the endcap.
Cylinder kit
1. Position pump on its side.
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
10 |
©
Danfoss | April 2017
AX00000305en-US0101