Service guide | Disassembling and assembling iSave 21 vane pump with upgrade kit 180F4161
7
180R9402 | 521B1455 | DKCFN.PI.003.T1.02 | 10.2017
7.
Gently place the rotor in the bearing.
8.
Position the 8 new vanes in the rotor.
The pins may be moved by using a
screwdriver.
9.
Check that all vanes are positioned
correctly.
10. One vane is
NOT
positioned correctly.
11. Replace the new O-ring on the flange and
wet the flange properly with clean filtered
water.
12. Position the new side plate over the guide
pin.