background image

Assembling the Current Sensor Cylinder Busbars in D2h/D4h/D7h/D8h Drives

WARNING

NOMEX SLEEVES REQUIRED

The Nomex sleeves are required to maintain proper electrical protection. Failure to install the Nomex sleeves can result in
personal injury or equipment damage.

Do not discard the Nomex sleeves.

Use the following steps to assemble the current sensor cylinder busbars in D2h/D4h/D7h/D8h drives.

1.

Place the 3 Nomex sleeves over the cylinder busbars,
1 per busbar.

2.

Insert 3 M8x70 screws through the center of the
busbars, 1 screw per busbar.

3.

The cylinder busbars are inserted through the centers
of the current sensors when installing the current
sensors in the drive. See 

300 A/500 A Current Sensor

Kit for D2h/D4h/D7h/D8h Drives

 installation

instruction.

1

Nomex  sleeve

2

Cylinder  busbar

3

M8x70  screw

Illustration 1.3 Current Sensor Cylinder Busbar Assembly in

D2h/D4h/D7h/D8h Drives

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on
order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss
and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss A/S
Ulsnaes 1
DK-6300 Graasten
vlt-drives.danfoss.com

 

*MI70Z202*

MI70Z202

130R0842

08/2018

Summary of Contents for 176F6757

Page 1: ...ltages when connected to mains voltage Improper installation and installing or servicing with power connected can cause death serious injury or equipment failure To avoid death serious injury or equipment failure Only use qualified electricians for the installation Disconnect the drive from all power sources before installation or service Treat the drive as live whenever the mains voltage is conne...

Page 2: ...it description Installation instruction 176F6517 176F6516 300 A D1 retro fit kit 300 A Current Sensor Kit for D1h D3h D5h D6h Drives 176F6757 176F3752 300 A D2 retro fit kit 300 A 500 A Current Sensor Kit for D2h D4h D7h D8h Drives 176F6756 176F3737 500 A D2 retro fit kit 300 A 500 A Current Sensor Kit for D2h D4h D7h D8h Drives Table 1 4 Comparison of Current Sensor Cylinder Busbar Kits Installat...

Page 3: ...er of the busbars and place the busbar mounting frame 1 screw per busbar The busbar with the red marking is the V busbar and is mounted in the middle 3 Retain 3 M6x16 screws to fasten the busbar mounting frame in the drive when installing the current sensors The cylinder busbars are inserted through the centers of the current sensors Refer to 300 A Current Sensor Kit for D1h D3h D5h D6h Drives ins...

Page 4: ...current sensors in the drive See 300 A 500 A Current Sensor Kit for D2h D4h D7h D8h Drives installation instruction 1 Nomex sleeve 2 Cylinder busbar 3 M8x70 screw Illustration 1 3 Current Sensor Cylinder Busbar Assembly in D2h D4h D7h D8h Drives Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its produc...

Reviews: