Assembling the Current Sensor Cylinder Busbars in D2h/D4h/D7h/D8h Drives
WARNING
NOMEX SLEEVES REQUIRED
The Nomex sleeves are required to maintain proper electrical protection. Failure to install the Nomex sleeves can result in
personal injury or equipment damage.
•
Do not discard the Nomex sleeves.
Use the following steps to assemble the current sensor cylinder busbars in D2h/D4h/D7h/D8h drives.
1.
Place the 3 Nomex sleeves over the cylinder busbars,
1 per busbar.
2.
Insert 3 M8x70 screws through the center of the
busbars, 1 screw per busbar.
3.
The cylinder busbars are inserted through the centers
of the current sensors when installing the current
sensors in the drive. See
300 A/500 A Current Sensor
Kit for D2h/D4h/D7h/D8h Drives
installation
instruction.
1
Nomex sleeve
2
Cylinder busbar
3
M8x70 screw
Illustration 1.3 Current Sensor Cylinder Busbar Assembly in
D2h/D4h/D7h/D8h Drives
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on
order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss
and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss A/S
Ulsnaes 1
DK-6300 Graasten
vlt-drives.danfoss.com
*MI70Z202*
MI70Z202
130R0842
08/2018