Installation Instructions for E3h/E4h Drives

1

Fan  housing

4

Screw  (T25)

2

Mounting pin (inside housing)

5

Cable access hole

3

Fan

6

Retaining clip

Illustration 1.3 Top Fan in E3h/E4h Drives

Removing the Top Fan from E3h/E4h Drives

To remove the top fan assembly from E3h or E4h drives, use
the following steps. Refer to 

Illustration 1.3

.

1.

Unfasten 4 screws (T25) and remove the upper front
cover of the drive.

2.

Remove 2 screws (T25) from the fan housing on top
of the drive.

3.

Slide the fan housing and 2 fans out from under the
retaining clips.

4.

Inside the drive, unplug the in-line connector
attaching the fan cable to the fan to be replaced.

5.

Feed the cable through the cable access hole on top
of the drive.

6.

Lift the fan from the pins in the fan housing.

Installing the Top Fan in E3h/E4h Drives

To replace the top fan assembly in E3h and E4h drives, use the
following steps. Refer to 

Illustration 1.3

.

1.

Position the new fan over the pins in the fan
housing. Check that the air direction arrows point
upward and away from the drive when installed.

2.

Feed the fan cables through the cable access hole in
the top plate near the fan vent.

3.

Attach the in-line cable connectors inside the drive
enclosure.

4.

Slide the fan housing and 2 fans into position under
the retaining clips on top of the drive.

5.

Secure 2 screws (T25) in the fan housing.

6.

Replace the upper front cover on the drive, and
fasten with 4 screws (T25).