2 Safety

2.1 Qualified Personnel

Correct and reliable transport, storage, installation, operation, and maintenance are required for the trouble-free and safe operation of
the drive. Only qualified personnel are allowed to install and operate this equipment.

Qualified personnel are defined as trained staff, who are authorized to install, commission, and maintain equipment, systems, and
circuits in accordance with pertinent laws and regulations. Also, the qualified personnel must be familiar with the instructions and
safety measures described in this manual.

2.2 Safety Precautions

WARNING

DISCHARGE TIME

The drive contains DC-link capacitors, which can remain charged even when the drive is not powered. High voltage can be
present even when the warning indicator lights are off.
Failure to wait the specified time after power has been removed before performing service or repair work could result in death
or serious injury.

-

Stop the motor.

-

Disconnect AC mains, permanent magnet type motors, and remote DC-link supplies, including battery back-ups, UPS, and
DC-link connections to other drives.

-

Wait for the capacitors to discharge fully. The minimum waiting time is specified in the table 

Discharge time

 and is also

visible on the nameplate on top of the drive.

-

Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors
are fully discharged.

Table 1: Discharge Time

Minimum waiting time (minutes)

4

7

15

20

30

40

200–240 V

0.25–3.7 kW

(0.34–5 hp)

5.5–37 kW

(7.5–50 hp)

380–500 V

0.25–7.5 kW

(0.34–10 hp)

11–75 kW

(15–100 hp)

90–200 kW

(150–350 hp)

250–500 kW

(450–750 hp)

250–800 kW

(450–1350 hp)

315–500 kW

(500–750 hp)

400 V

90–315 kW

(125–450 hp)

500 V

110–355 kW

(150–450 hp)

Safety

Installation Guide  | 1000 Hz Control Card MK-I

AN281754171207en-000101 / 130R0878

2 | Danfoss A/S © 2018.11

Summary of Contents for 1000 Hz Control Card MK-I

Page 1: ...n VLT AutomationDrive FC 302 series Update to 1000 Hz output frequency The drive is subject to export control ECCN 3A225 1 2 Trademarks VLT is a registered trademark for Danfoss A S 1 3 Item Supplied...

Page 2: ...after power has been removed before performing service or repair work could result in death or serious injury Stop the motor Disconnect AC mains permanent magnet type motors and remote DC link supplie...

Page 3: ...y or a local Danfoss partner company the extra 1000 Hz label which is in the box must be placed visible on the drive The label indicates that the drive is updated to run with maximum 1000 Hz speed Fil...

Page 4: ...0B1109 and does not have all the new functions which are in the new MK II control card Furthermore new software cannot be flashed into this control card Safety Installation Guide 1000 Hz Control Card...

Page 5: ...Remove the LCP and the blind cover 1 2 e30bf717 11 1 LCP 2 Blind cover Illustration 2 LCP and Blind Cover e30bf718 11 Illustration 3 Removing LCP Installation Installation Guide 1000 Hz Control Card M...

Page 6: ...stration 5 Removing LCP Cradle 3 Remove all control cables from the metal bracket spring loaded 4 Remove any A B or C options that may be installed 5 Remove the I O terminals Installation Installation...

Page 7: ...e shield 1 3 2 e30bf722 11 1 Cable shield 3 T10 screws 2 MCO ribbon cable Illustration 7 Location of Cable Shield Screws and MCO Ribbon Cable 8 Unscrew the 2 T10 screws holding the control card EMC sh...

Page 8: ...trol card from the upper right socket Avoid overbending and contact with electronic components 1 2 e30bf724 11 1 Control card 2 T10 screws Illustration 9 Control Card and T10 Screws 12 Re assemble the...

Page 9: ...Installation Installation Guide 1000 Hz Control Card MK I AN281754171207en 000101 130R0878 9 Danfoss A S 2018 11...

Page 10: ...ies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property...

Reviews: