1 Introduction

1.1 Purpose of this Installation Guide

This installation guide provides information for quick installation of the control card in VLT® AutomationDrive FC 302 series.

Update to 1000 Hz output frequency. The drive is subject to export control, ECCN 3A225.

1.2 Trademarks

VLT

®

 is a registered trademark for Danfoss A/S.

1.3 Item Supplied

VLT® FC 302 1000 Hz Control Card MK-I (code number: 134B6628).

1.4 Tools

Torx 10 screwdriver.

Flat-head screwdriver.

1.5 Additional Items Required

VLT® AutomationDrive FC 302.

AN281754171207en-000101 / 130R0878 | 1

Danfoss A/S © 2018.11

Summary of Contents for 1000 Hz Control Card MK-I

Page 1: ...n VLT AutomationDrive FC 302 series Update to 1000 Hz output frequency The drive is subject to export control ECCN 3A225 1 2 Trademarks VLT is a registered trademark for Danfoss A S 1 3 Item Supplied...

Page 2: ...after power has been removed before performing service or repair work could result in death or serious injury Stop the motor Disconnect AC mains permanent magnet type motors and remote DC link supplie...

Page 3: ...y or a local Danfoss partner company the extra 1000 Hz label which is in the box must be placed visible on the drive The label indicates that the drive is updated to run with maximum 1000 Hz speed Fil...

Page 4: ...0B1109 and does not have all the new functions which are in the new MK II control card Furthermore new software cannot be flashed into this control card Safety Installation Guide 1000 Hz Control Card...

Page 5: ...Remove the LCP and the blind cover 1 2 e30bf717 11 1 LCP 2 Blind cover Illustration 2 LCP and Blind Cover e30bf718 11 Illustration 3 Removing LCP Installation Installation Guide 1000 Hz Control Card M...

Page 6: ...stration 5 Removing LCP Cradle 3 Remove all control cables from the metal bracket spring loaded 4 Remove any A B or C options that may be installed 5 Remove the I O terminals Installation Installation...

Page 7: ...e shield 1 3 2 e30bf722 11 1 Cable shield 3 T10 screws 2 MCO ribbon cable Illustration 7 Location of Cable Shield Screws and MCO Ribbon Cable 8 Unscrew the 2 T10 screws holding the control card EMC sh...

Page 8: ...trol card from the upper right socket Avoid overbending and contact with electronic components 1 2 e30bf724 11 1 Control card 2 T10 screws Illustration 9 Control Card and T10 Screws 12 Re assemble the...

Page 9: ...Installation Installation Guide 1000 Hz Control Card MK I AN281754171207en 000101 130R0878 9 Danfoss A S 2018 11...

Page 10: ...ies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property...