7
© Danfoss 05/2011
VIUHR402
Danfoss Heating Solutions
Setting of room temperature
1. Make sure actual room temperature is shown in the
display.
2. Press the up/down selector
to set the desired room
temperature value. SET is shown in the display.
3. When releasing the up/down selector
the display
returns to actual temperature.
Note: The thermostat regulates the floor heating system
according to room temperature set point, within the
maximum and minimum limitations defined for the
floor surface temperature.
Room temperature limitation
1. Make sure actual room temperature is shown in the
display.
2. Press the push button
until SET MAX is shown in
the display.
3. Press the up/down selector
to set the maximum
room temperature limitation.
4. Press the push button
shortly, SET MIN is shown in
the display.
5. Press the up/down selector
to set the minimum
room temperature limitation.
6. Press the push button
shortly and the actual floor
surface temperature is shown in the display.
Instruction
CF-RF Room Thermostat with Infrared Floor Sensor