3 Operation
3.1 Bridge Control Panel
The BCP is the primary user interface for an installed operational VDR. It serves two purposes:
•
Alarm (caution) display
•
Interface for initiating VDR self-test (Operational Performance Test)
3.1.1 Alarm display
The VDR will generate an alarm message (caution) if a system error is detected. An alarm message
will be displayed on the BCP and the yellow caution indicator will be illuminated. No audible alarm
will be generated and alarms should not be acknowledged. Alarm messages will be cleared and the
caution indicator turned off when the cause of error is resolved.
3.1.2 Self-test – Operational Performance Test
An Operational Performance Test (OPT) of the VDR must be carried out regularly, and always after
service and maintenance which may affect the operation of the VDR. An OPT is best done while
the vessel is en route and all navigation equipment is switched on. A service agent must be
contacted if the OPT report shows problems which cannot be fixed by the master on the vessel.
Click on “F2” and follow the instructions in order to carry out an OPT.
3.1.3 Setting the display brilliance level to default
Pressing the DIM bottom for 5-7 seconds will restore the display brilliance level.