Call 

When a call is coming in this 

LED

 lights up indicating a call is coming in. 

When the Ringer is not switched off (this can be done by a small screwdriver pushing down 

the hidden switch underneath the hole labeled “ Ringer off” ) you will hear a ringer melody 

coming from the TelCom unit until the moment the Hook switch is pushed. Now the caller is 

connected to the TelCom unit. 

 

Ringer off 

Behinf this small hole you will find switch that can switch off the internal ringer (small 

speaker) This can be done by a small screwdriver pushing down the hidden switch underneath 

the hole labeled “ Ringer off” 

 

Send 

Behind this small hole in the front panel there is a trimmer that adjust the outgoing level to 

the caller coming from the mixer. Adjustment has to be performed once in cooperation with a 

caller that can give feedback about the level she/he hears. 

 

Receive 

Behind this small hole in the front panel there is a trimmer that adjust the incoming level from 

the caller going to the mixer. Adjustment has to be performed once in cooperation with a 

caller that can give feedback about the level she/he talks into the phone. This adjustment has 

to be a balance between receive level on the TelCom unit and input gain of the connected 

mixer. 

 

Sidetone 

This hidden trimmer needs to adjusted to a position where the outgoing level is minimally 

heard in the receive level coming from the caller. 

 

 

Summary of Contents for TelCom

Page 1: ...Manual page 1 TelCom USER MANUAL Version1 02 ...

Page 2: ...nterface All functions are self explanatory and you will certainly appreciate the ergonomics of this design We are confident that you will be using the TelCom for many years to come and wish you a lot of success in your application With kind regards Duco de Rijk President D R ELECTRONICA WEESP B V Rijnkade 15B 1382 GS WEESP HOLLAND The Netherlands Phone 0294 418 014 Fax 0294 416 987 Website http w...

Page 3: ...ed in radio and television broadcasting applications allowing external callers to be connected to the studio mixing console Most of the other units are supplied to communication operations allowing extremely effective conversion between 4 wire audio circuits and standard telephone lines Specs AUDIO PROGRAM IN AND OUT Connectors Jack stereo 6 3mm and Cinch connectors Input impedance 5kOhm transform...

Page 4: ...witch allows you to turn the internal buzzer off by inserting a small screwdriver Send This trimmer adjust the level of the audio sent to the telephone caller which is connected to the SEND jack cinch connector on the rear panel Receive This trimmer adjust the level of the audio coming in from the telephone caller which is connected to the RECEIVE jack cinch connector on the rear panel Side tone W...

Page 5: ...he Hybrid s phone output on the RJ 11 connector labeled PHONE This can be done with standard available cable assemblies from your local phone shop Now the hybrid is interfaced fully balanced between your telephone appliance and its connection to the outside world The hybrid can now split the send and return signals Now connect the hybrid s balanced audio output labeled RECEIVE to a preferable bala...

Page 6: ...CTORS PHONE WALL RJ 11 FUNCTION CONNECTION Pin 1 n c Pin 2 A telephone line In out Pin 3 B telephone line In out Pin 4 n c WIRING OF AUDIO IN AND OUTPUTS STEREO JACK TO LINE INPUT TO CLEANFEED OUTPUT TYPE CONNECTION Screen Screen ground Audio ground Ring Non phase cold Audio Tip Phase hot Audio MONO CINCH TO LINE INPUT TO CLEANFEED OUTPUT Screen Non phase cold ground Audio ground Tip Phase hot Aud...

Page 7: ...nnect the caller to the mixing console by pushing the HOOK switch Now listen by means of a PFL CUE switch on your mixer to the caller and adjust while talking the Side tone trimmer so that the outgoing signal your voice is best attenuated Note the line balancing to your own telephone station has to be performed one time only when no changes are made to the telephone system in your place The maximu...

Page 8: ...ed Ringer off Send Behind this small hole in the front panel there is a trimmer that adjust the outgoing level to the caller coming from the mixer Adjustment has to be performed once in cooperation with a caller that can give feedback about the level she he hears Receive Behind this small hole in the front panel there is a trimmer that adjust the incoming level from the caller going to the mixer A...

Page 9: ...asen am Stecker passen dieStecker vonTelefonen immernurinF Buchsen Anschlussdose rlE 3 f Srcc r FtirdenBetrieb desTelefons unddesTelefonhybrids istdieBelegung 1 und2 erforderlich RJ I l Stecker Western Stecker Belegung Telefonhybrid PHON E LlNE 6 Kontakte davon 4 belegt Westernstecker 6P4C Diebeiden iuBerenKontakte fehlen 1 frei 2 frei 3 Laoderal a Leitungsader 4 Lboder b1 b Leitungsader 5 frei 5 ...

Page 10: ...iemens 5 Kontakte davon 4 belegt Westernstecker 5P4C Diebeiden iuBerenKontakte fehlen F0rdenBetrieb bestimmter Telefone muss einangepasstes Kabel venrendetwerden sonstistkein Betrieb desTelefons m6glich 1 frei 2 Lboderb1 b Leitungsader 3 frei 4 frei 5 Laodera1 a Leitungsader 6 frei DerHersteller hatmeistens folgendes Kabel im Lieferumfang TAE F RJ11 1 Laodera1 a Leitungsader 5 Laodera1 a Leitungsa...

Page 11: ... istdie Beleouno desRl77 Steckerc auf 5 und2 zudndernlll 1 frei 2 lrei 3 a Leitungsader 4 b Leitungsader 5 frei 6 frei 1 frei 2 lrei 3 a Leitungsader 4 b Leitungsader 5 frei 6 frei e ffir tffir r g ffi tffir _J 1 frei 2 trei 3 a Leitungsader 4 b Leitungsader 5 frei 6 frei oder 1 frei 2 b Leitungsader 3 frei 4 trei 5 a Leitungsader 6 frei www michae l schoebel de Seite3von3 t2l2008 ...

Page 12: ...ons All Complies with the following product specifications Security EN 60950 1988 A1 A2 EMC CISPR 22 1985 EN 55022 1988 klasse B EN 50082 1 1992 IEC 801 2 1991 prEN 55024 2 1992 3kV CD 8kV AD IEC 801 3 1984 prEN 55024 3 1991 3 V m IEC 801 4 1988 prEN 55024 4 1992 0 5kV signal cables 1 kV power cables Additional info The product complies herewith to the following rules Low voltage 73 23 EEG EMC rul...

Page 13: ...athing At what potential is current dangerous Well the first feeling of current is a tingle at 0 001 Amp of current The current between 0 1 Amp and 0 2 Amp is fatal Imagine that your home fuses of 20 Amp can handle 200 times more current than is necessary to kill How does resistance affect the shock a person feels A typical resistance between one hand to the other in dry condition could well over ...

Page 14: ...Manual page 11 TelCom SERVICE MANUAL Upon request ...

Page 15: ...Manual page 11 TelCom TelCom TelCom TelCom SERVICE MANUAL Upon request ...

Page 16: ......

Page 17: ...st 150 10500084 Insul plate 9 5 randapp PVC 1 0000 st 130 10700625 Kartelring M3 buitenvertand 2 0000 st 330 10250387 Led 3mm red SLR 03A510 020 2 0000 st 10 20851515 PCB ins TelCom 1 0000 st 140 10700600 Parker 2 9x6 5 verz zwart 1 0000 st 80 10700656 Plakvoet SJ 5012 4 0000 st 320 10450210 Pushb SiF 2 8 red square 1 0000 st 310 10450010 Pushb TAK12x12 107 A3 3 Black 1 0000 st 90 10800956 Schuimb...

Page 18: ...9 Piezo buzzer PKM13EPYH4002 BO 1 0000 st 60 10250345 Rect B80C1500 round 1 0000 st 510 10350765 Resistor 1M0 5 1 4W 1 0000 st 480 10350729 Resistor 1k0 5 1 4W 2 0000 st 490 10350731 Resistor 1k5 5 1 4W 1 0000 st 500 10350732 Resistor 1k8 5 1 4W 3 0000 st 540 10350733 Resistor 2k2 5 1 4W 2 0000 st 630 10350772 Resistor 5M1 5 1 4W 1 0000 st 660 10350738 Resistor 5k6 5 1 4W 1 0000 st 440 10350848 Re...

Page 19: ...ectronica Weesp B V Bedrijf 100 Positie Artikel Omschrijving Leveranciercode Netto Vrd Verval code hoeveelheid eh datum Maakartikel 20851515 PCB ins TelCom Stuklijsteenheid 1 st 150 10250350 Zenerdiode 18V0 400mW 1 0000 st 360 10250369 Zenerdiode 5V1 400mW 1 0000 st ...

Reviews: