Part NO: 212-0024-8S 11 September 24th,
To set the time delay follow these steps:
1. Locate the dip switch on the PDU.
2. Refer to the attached label or Table 1 to determine the switch settings.
3. Use a pen tip or other suitably small tool to set the switches. This will select
the time increments to the output off time delay
.
Table 1 Time Delay Switch Settings
Factory Default = 2 Hours
TIME
SW-1
SW-2
SW-3
SW-4
2 MIN.
ON
ON
ON
ON
10
MIN.
OFF
ON
ON
ON
30
MIN.
ON
OFF
ON
ON
1 HR.
OFF
OFF
ON
ON
2 HR.
ON
ON
OFF
ON
3 HR.
OFF
ON
OFF
ON
4 HR.
ON
OFF
OFF
ON
5 HR.
OFF
OFF
OFF
ON
6 HR.
ON
ON
ON
OFF
7 HR.
OFF
ON
ON
OFF
8 HR.
ON
OFF
ON
OFF
9 HR.
OFF
OFF
ON
OFF
10 HR.
ON
ON
OFF
OFF
11 HR.
OFF
ON
OFF
OFF
12 HR.
ON
OFF
OFF
OFF
13 HR.
OFF
OFF
OFF
OFF