Operation with D6 or D12

Select the controller setup E9.

Within the D12 amplifier this is available in "Dual Channel" and "Mix
TOP/SUB" mode.

IMPORTANT!

Up to a total of two E9 loudspeakers can be driven by each D6 or D12
amplifier channel.

In applications with low continuous levels and low ambient temperatures
up to three cabinets can be connected to a D12 channel.

When the D12 is operated in "Mix TOP/SUB" mode, the E9 cabinet
and a respective active subwoofer can be linked together locally and
fed by a single 4-wire cable from either amplifier output connector.

To apply SenseDrive for the subwoofer, EP5 connectors and 5-wire
cables have to be used. When operated in "Mix TOP/SUB" mode,
subwoofers have to be fed from the output B connector of the D12
amplifier.

Controller settings

For acoustic adjustment the settings CUT and HFA can be selected.

CUT circuit

Set to CUT, a high pass filter with a 110 Hz cut off frequency is inserted
in the controller signal path. The E9 is now configured for use with d&b
active subwoofers.

HFA circuit

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Fig. 3: Frequency response of HFA circuit 

In HFA mode (High Frequency Attenuation), the HF response of the E9 is
rolled off. The HFA circuit provides a natural, balanced frequency
response when a unit is placed close to listeners in near field or delay
use.

High frequency attenuation begins gradually at 1 kHz, dropping by
approximately 3 dB at 10 kHz. This roll off mimics the decline in
frequency response experienced when listening to a system from a
distance in a typically reverberant room or auditorium.

Operation with E-PAC

Fig. 4: E-PAC configuration for E9
(E-PAC version 2)

To drive E9 cabinets, the E-PAC has to be configured to E9 mode.

For an E-PAC version 2, the configuration is selected by setting the
appropriate DIP switches on the rear panel. 

For an E-PAC version 3, the configuration is set via the encoder in
conjunction with an LCD.

Selecting E9 mode enables the E-PAC to drive one E9 cabinet. LO IMP
mode allows the E-PAC to drive up to two E9 cabinets with a 6 dB
reduction of input level to the loudspeakers.

The CUT and HFA settings are available. The characteristics of the CUT
and HFA settings are explained in the previous section "Operation with
D6 or D12 - Controller settings".

E9 Manual 

(3.1 EN)

Page 5 of 8

Summary of Contents for E9

Page 1: ...E9 Manual 3 1 EN ...

Page 2: ...9 Manual Version 3 1 EN 03 2008 D2071 E 03 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the syste...

Page 3: ...he accessories as detailed in our specific Mounting instructions or in our Flying system and rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessori...

Page 4: ...L shaped metal plate at the bottom of the cabinet also incorporates a handle four M10 threaded inserts and a socket to accept a loudspeaker stand NOTICE Only operate E9 loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Connections 1 2 3 4 5 1 2 3 4 5 passive crossover Fig 2 Connector wiring The E9 cabinet is fitted with a pair o...

Page 5: ...15 20 25 30 20 100 1k 10k 20k Fig 3 Frequency response of HFA circuit In HFA mode High Frequency Attenuation the HF response of the E9 is rolled off The HFA circuit provides a natural balanced frequency response when a unit is placed close to listeners in near field or delay use High frequency attenuation begins gradually at 1 kHz dropping by approximately 3 dB at 10 kHz This roll off mimics the d...

Page 6: ...rs BX switch and indicator When the E9 is used with the passive E15 BX subwoofer i e E9 and E15 BX are linked to the same amplifier output the BX switch should be selected The LF level boosted by the bass extension cabinet is then attenuated by 3 dB thereby increasing headroom at bass frequencies SUB CUT and BX both selected Selecting the CUT and BX switches activates a lowpass filter The module n...

Page 7: ...e field with P1200A 128 dB SPLmax peak pink noise test signal with crest factor of 4 Input level 100 dB SPL 1 m 13 dBu E9 loudspeaker Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 200 800 W Nominal dispersion angle horizontal 90 vertical 20 30 Components 12 driver 2 compression driver Connections 2 x EP5 Pin assignments 1 2 optional 2 x NL4 Pin assignments 1 1 Weight 26 kg 57 lb ...

Page 8: ... all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contractual...

Reviews: