Controller settings

For acoustic adjustment the functions CUT, HFA, HFC and CPL can be
selected.

CUT circuit

Set to CUT, the T10 low frequency level is reduced. The T10 is now
configured for use with the T-SUB or other d&b active subwoofers.

HFA circuit (T10 PS setup only)

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Fig. 5: Frequency response correction of
HFA circuit 

In HFA mode (High Frequency Attenuation), the HF response of the T10
system is rolled off. HFA provides a natural, balanced frequency
response when a unit is placed close to listeners in near field or delay
use.

High Frequency Attenuation begins gradually at 1 kHz, dropping by
approximately 3 dB at 10 kHz. This roll-off mimics the decline in
frequency response experienced when listening to a system from a
distance in a typically reverberant room or auditorium.

HFC circuit (T10 Arc/Line setups only)

Fig. 6: Frequency response correction of
HFC circuit 

Selecting the HFC (High Frequency Compensation) circuit compensates
for loss of high frequency energy due to absorption in air when
loudspeakers are used to cover far field listening positions.

The HFC circuit has two settings (HF1, HF2) for different distance ranges
the cabinets have to cover. The settings should be used selectively, only
for those cabinets covering the respective distances, HF1 for distances
larger than 25 m (80 ft) and HF2 for distances larger than 50 m
(160 ft).

The compensation is adjusted for a typical relative humidity of 40 %.
With lower humidity the absorption by air increases therefore the
distances where the respective HFC setting provides a correct
equalization are shorter than indicated above.

Using the HFC function provides the correct sound balance between
close and remote audience areas, whilst all amplifiers driving the array
can be fed with the same signal.

CPL circuit

Fig. 7: Frequency response correction of
CPL circuit

The CPL (Coupling) circuit compensates for coupling effects between the
cabinets; these effects increase as the length of the line array is
extended. CPL begins gradually at 1 kHz, with the maximum attenuation
below 400 Hz, providing a balanced frequency response when T10
cabinets are used in arrays of four or more. The function of the CPL
circuit is shown in the diagram opposite and can be set in dB
attenuation values between –9 and 0, or a positive CPL value which
creates an adjustable low frequency boost around 65 Hz (0 to +5 dB).

Note:

Make sure that all cabinets within the line array are operated
with the same CPL setting.

T10 Manual

(1.0 EN)    

Page 6 of 10

Summary of Contents for T10

Page 1: ...T10 Manual 1 0 EN...

Page 2: ...ormation T10 Manual Version 1 0 EN 12 2008 D2600 EN 01 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for futu...

Page 3: ...e accessories as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile de...

Page 4: ...onfigurations The front of the loudspeaker cabinet is protected by a rigid metal grill in front of an acoustically transparent foam NOTICE Only operate T10 loudspeakers with a correctly configured d b...

Page 5: ...and Mix TOP SUB mode Up to a total of four T10 loudspeakers can be driven by each channel of the D6 or D12 amplifiers T10 Arc and T10 Line setups These setups are selected when T10 loudspeakers are u...

Page 6: ...stance ranges the cabinets have to cover The settings should be used selectively only for those cabinets covering the respective distances HF1 for distances larger than 25 m 80 ft and HF2 for distance...

Page 7: ...sobar diagram T10 point source vertical Altering the HF dispersion Fig 12 Rotating the horn shown without front grill for better illustration Swapping between point and line source setups is performed...

Page 8: ...th D12 130 dB SPLmax peak pink noise test signal with crest factor of 4 Input level 100 dB SPL 1 m 13 dBu T10 loudspeaker Nominal impedance 16 ohms Power handling capacity RMS peak 10 ms 200 800 W Nom...

Page 9: ...h the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at ww...

Page 10: ...D2600 EN 01 12 2008 d b audiotechnik GmbH d b audiotechnik GmbH Eugen Adolff Str 134 D 71522 Backnang Germany Phone 49 7191 9669 0 Fax 49 7191 95 00 00_______...

Reviews: