Manual 

(1.4 EN)

   

Summary of Contents for R70

Page 1: ...R70 Ethernet to CAN interface Manual 1 4 EN ...

Page 2: ...sion 1 4 EN 04 2009 D2402 EN 01 Copyright 2009 by d b audiotechnik GmbH all rights reserved d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany Telephone 49 7191 9669 0 Fax 49 7191 95 00 00 E mail docadmin dbaudio com Internet www dbaudio com ...

Page 3: ... 3 R70 operation and configuration 12 3 1 Physical setup 12 3 2 IP address 12 3 3 Direct connection 12 3 4 LAN network with DHCP server 13 3 5 LAN network without DHCP server 14 3 6 R70 Web interface 15 3 6 1 Device Info 15 3 6 2 LAN and CAN Parameters 15 4 R70 accessories and anti theft protection LOCK 17 4 1 Mounting clamp 17 4 1 1 Attaching the mounting clamp 17 4 2 Anti theft protection LOCK 1...

Page 4: ...use The R70 Ethernet to CAN interface provides two RJ 45 CAN connectors with a built in switchable terminator as well as a LAN connector The R70 contains a web interface for configuration using a standard web browser Up to five R70 interfaces in TCP IP mode may be connected to a PC and simultaneously operated by the R1 software The R70 is designed to connect the d b Remote network CAN Bus to a PC ...

Page 5: ...erate the device Qty d b Code Description 1 Z6124 R70 Ethernet to CAN interface 1 1 Power supply 2 including 4 x AC input plugs specific to the following territorial regions Europe UK USA and Australia 2 Z6116 RJ 45 M Terminator 3 1 CD ROM 4 containing the R70 manuals and additional documentation TI 312 Additionally the AcrobatReader in its current version is provided to allow the documents to be ...

Page 6: ...nnector CAN 2 x RJ 45 connectors wired in parallel Hardware Controller 16 Bit Program Flash 256 kB Data Flash 8 MB SRAM Size 256 kB EEPROM Size 8 kB Additional features CAN galvanically isolated CAN Specification 2 0 A B CAN Bus coupling High Speed according to ISO 11898 galvanically isolated Max CAN Baud Rate 1 Mbit s Ethernet Specification Ethernet 10 100 M Base F IEEE 802 3u Power over Ethernet...

Page 7: ... plugs to allow for connection to the following mains sockets Europe UK USA and Australia Fitting Exchanging the AC input plug To fit or exchange the AC input plug proceed as follows 1 Slide in the respective AC input plug until it snaps into place 2 To exchange the plug press the button B and slide out the plug 2 1 2 LAN connector 1 1 The RJ 45 connector type B white colored coding ring is locate...

Page 8: ...d shielded RJ 45 connectors must be used to connect the devices of the d b Remote network CAN Bus The cable shielding must be connected to both sides of the RJ 45 connector as the CAN Ground is routed via the cable shielding RJ 45 2 Pin Signal Remark 1 45 8 1 2 3 4 CAN_H CAN high bus line active high 5 CAN_L CAN low bus line active low 6 7 8 Shell GND CAN ground Table 2 RJ 45 CAN Bus pin assignmen...

Page 9: ...ace has a built in switchable terminator which can be activated when only one of its CAN connectors is used refer to the wiring examples given in the following section To terminate the interface Set the termination switch 3a to TERMINATE The corresponding status LED 3b lights up In this case both RJ 45 connectors are terminated as shown in the graphic opposite Note The two RJ 45 M terminators supp...

Page 10: ...f the CAN Bus segment Daisy chain RJ 45 M Terminating connector CAN Bus D12 LEVEL PUSH MENU MUTE POWER A B ON OFF OVL GR ISP OVL GR ISP D12 LEVEL PUSH MENU MUTE POWER A B ON OFF OVL GR ISP OVL GR ISP Termination switch set to off Daisy chain RJ 45 M Terminating connector CAN Bus D12 LEVEL PUSH MENU MUTE POWER A B ON OFF OVL GR ISP OVL GR ISP D12 LEVEL PUSH MENU MUTE POWER A B ON OFF OVL GR ISP OVL...

Page 11: ...tate Flashing CAN message received through an active Ethernet connection ON Green 7 Off Device is shut off On Status OK Flashing Initializing 2 2 3 RESET R R The RESET switch push button is located on the right hand side panel of the device and allows for a reset of the device to factory default To reset the device proceed as follows 1 Disconnect the power from the device 2 Press and hold the rese...

Page 12: ...t be adapted manually The R70 IP address is set to 192 168 1 70 by factory default see also the label sticker on the rear panel of the R70 3 3 Direct connection To access the R70 manually assign an IP address to the PC on your network with the same subnet as the R70 Proceed as follows 1 From the Start Settings menu select the Network Connection associated with your network adapter 2 Select Interne...

Page 13: ...on is enabled by default 1 Connect the R70 to your network and an IP address is assigned by the DHCP server 2 Start the respective d b software e g R1 Edit mode and select CAN from the Extras Options menu The program scans for connected interfaces and all devices found are listed This may take several seconds 3 Right click on an R70 entry in the list and select Configure Interface to access the R7...

Page 14: ...work To do so first proceed as described in the previous section Direct connection to gain access to the R70 1 Select the LAN Parameters tab from the R70 web interface and disable Obtain an IP address automatically 2 Enter the desired Host name the respective IP address and Subnet mask 3 Click Save to confirm and execute a Device Restart Page 14 of 20 R70 Ethernet to CAN interface Manual ...

Page 15: ...Errors The respective error message is reset after the related fault is solved Device Restart The device is rebooted and the current session is disconnected Factory Default The device is set to the default IP address and DHCP is enabled The R70 IP address is set to 192 168 1 70 by factory default see also the label sticker on the rear panel of the R70 3 6 2 LAN and CAN Parameters NOTICE The Advanc...

Page 16: ... settings below can be assigned automatically if the on site network supports this capability Otherwise please consult the responsible network administrator for the appropriate IP settings Host Name Name to identify the R70 within a network This name must be unique IP Address Unique IP address according to IP v4 Standard Subnet Mask Corresponding subnet mask Obtain an IP address automatically Enab...

Page 17: ... TS 35 35 mm 1 4 inside an equipment cabinet 4 1 1 Attaching the mounting clamp The two clamp halves have different lengths For this reason we recommend you to align the clamp or the R70 in such a way that the short clamp half is located on the top panel of the device see graphic opposite 4 2 Anti theft protection LOCK A slot LOCK is located on the right hand side panel of the device and allows fo...

Page 18: ...mbH 4 3 Dimension drawings 54 2 1 0 4 4 0 2 36 1 4 Fig 7 Z6123 Bopla mounting clamp upright dimensions in mm inch Fig 8 Wall mounting with dimensions in mm inch Fig 9 Top hat rail mounting with dimensions in mm inch Page 18 of 20 R70 Ethernet to CAN interface Manual ...

Page 19: ...h declare that said product is in conformity with the provisions of the following EC directives including all applicable amendments 2004 108 EC Electromagnetic Compatibility 2006 95 EC Low Voltage IEC 60950 DIN EN 60950 2001 A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 5 2 Disposal WEEE symbol This symbol indicates...

Page 20: ...D2402 EN 01 04 2009 d b audiotechnik GmbH d b audiotechnik GmbH Eugen Adolff Str 134 D 71522 Backnang Germany Phone 49 7191 9669 0 Fax 49 7191 95 00 00 ...

Reviews: