IMPORTANT SAFETY INSTRUCTIONS

Explanation of graphical symbols

The lightning symbol within a triangle is intended to alert

the user to the presence of uninsulated "dangerous

voltages" within the unit’s chassis that may be of

sufficient magnitude to constitute a risk of electric shock

to humans.

 

The exclamation point within a triangle is intended to

alert the user to the presence of important operating and

service instructions in the literature accompanying the

product.

Before using this product, carefully read the

applicable items of the following safety instructions.

 

 

1. Keep these instructions for future reference.
2. Read these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. WARNING! To reduce the risk of fire or electric shock:

– Do not expose this unit to rain or moisture.
– Keep water or other liquids away from the unit.
– Do not place liquid filled containers, for example

beverages, on top of the unit.

– Do not operate the unit while it is wet or standing in liquid.

6. Always operate the unit with the chassis ground wire

connected to the electrical safety earth.
Do not defeat the safety purpose of a grounding-type plug. A

grounding-type plug has two blades and a third grounding

prong. The third prong is provided for your safety.
If the provided plug does not fit into your outlet, consult an

electrician for replacement of the obsolete outlet.

7. Do not use this unit if the power cord is damaged or frayed.

Protect the power cord from being walked upon or pinched,

particularly at the plugs and the point where it exits from the

apparatus.

8. The unit is intended for use in a 19" rack. Follow the mounting

instructions. When a rack on wheels is used, exercise caution

when moving the loaded rack to avoid injury from tipping

over.

9. Unplug this apparatus during lightning storms or when unused

for long periods of time.

 

10. Never connect an output pin to any other amplifier input or

output pin or to the earth (ground). This may damage the unit

or lead to electric shock.

11. Lay all cables connected to the unit carefully so that they

cannot be crushed by vehicles or other equipment and that no

one can either step on them or trip over them.

12. Refer all servicing to qualified service personnel. Servicing is

required when the apparatus has been damaged in any way

such as:

– Power-supply cord or plug is damaged.
– Liquid has been spilled into the unit.
– An object has fallen into the unit.
– The unit has been exposed to rain or moisture.
– The unit does not operate normally.
– The unit was dropped or the chassis is damaged.
– Do not remove top or bottom covers. Removal of the covers

will expose hazardous voltages. There are no user

serviceable parts inside and removal may void the warranty.

13. Use the mains plug as the disconnecting device and keep it

readily accessible. If the mains plug is not readily accessible

due to mounting in a 19" equipment cabinet, then the mains

plug for the entire rack must be readily accessible.

14. An experienced user must always supervise the equipment,

especially if inexperienced adults or minors are using the

equipment.

IMPORTANT SAFETY INSTRUCTIONS

 

d&b 5D Start-up manual 1.1 en

- preliminary -

3

Summary of Contents for preliminary XD 5D

Page 1: ...preliminary xD5D Start up manual 1 1 en...

Page 2: ...the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to t...

Page 3: ...upon or pinched particularly at the plugs and the point where it exits from the apparatus 8 The unit is intended for use in a 19 rack Follow the mounting instructions When a rack on wheels is used ex...

Page 4: ...connection 15 5 2 2 Analog audio input link connectors 16 5 2 3 ETH1 ETH2 Dante 16 5 2 4 OUTPUTS 17 5 2 5 GPI DC Hardware description 18 5 2 6 FAULT 18 5 3 Controls and indicators 19 5 3 1 Mains power...

Page 5: ...tionality and high complexity of the device this manual covers the basic safety instructions as well as the vital technical specifications and instructions for startup A full version of this manual Re...

Page 6: ...TPUTS connector sockets Connector type Euroblock 5 08 mm 4 1 3 pin Euroblock female Intended for the FAULT connector socket Connector type Euroblock 3 5 mm D2766 EN 01 d b 5D Start up manual Mains plu...

Page 7: ...ions is included with the device Please also refer to Chapter 5 1 Rack mounting and cooling on page 13 Pos Qty d b Code Description 5 2 Rack ears 6 1 19 Adapter Bridge 7 4 Dual connector plates 8 10 C...

Page 8: ...unweighted 330 VRMS 108 dB Analog input A weighting 240 VRMS 111 dB Dante input unweighted 240 VRMS 111 dB Dante input A weighting 180 VRMS 113 dB THD N Crosstalk THD N unweighted 20 20 kHz 4x 75 W 8...

Page 9: ...0 VAC 50 Hz mains supply The power rating of noise signals is defined as the maximum of the instantaneous output power divided by a factor of two The power of burst signals refers to the power during...

Page 10: ...ms 230 VAC 50 Hz 0 5 Source impedance all channels driven State Load ohms Mains current A RMS Power factor Input power W Output power W Power loss W BTU hr kCal hr Standby 0 1 0 17 4 4 14 3 AutoWakeup...

Page 11: ...4 7 0 97 0 97 490 540 350 350 140 190 478 648 120 163 Sinus max 1 s 8 ohms 4 ohms 10 2 10 4 100 VAC 60 Hz 0 2 Source impedance all channels driven State Load ohms Mains current A RMS Power factor Inpu...

Page 12: ...Chapter 5 2 3 ETH1 ETH2 Dante on page 16 5 DC Out GPI connector Refer to Chapter 5 2 5 GPI DC Hardware description on page 18 6 FAULT connector Refer to Chapter 5 2 6 FAULT on page 18 4 2 Controls an...

Page 13: ...evices at the top bottom front and rear 2 On one device don t matter which attach the dual connector plates 7 Ensure the countersinks faces to the top 3 Join the devices together 4 Redo the remaining...

Page 14: ...ase ensure that adequate cool airflow is provided Do not block or cover the front panel air intake or the vents on the rear panel If the amplifiers are installed in sealed cabinets e g in fixed instal...

Page 15: ...time to disconnect the device in case of malfunction or danger If the mains plug is not readily accessible due to mounting in a 19 rack or equipment cabinet then the mains plug for the entire rack or...

Page 16: ...ly when the speed is 1 Gbits A dual Ethernet port with a built in 2 port Ethernet switch 1 Gbits 100 Mbits peer to peer is provided enabling standard remote control via the d b Remote network OCA AES7...

Page 17: ...AWG 13 Ensure all contact screws are properly tightened Rated torque settings max 0 5 N m Screw driver size Phillips PH1 0 6 x 3 5 mm The amplifier is equipped with two Euroblock connector sockets fe...

Page 18: ...PIs 1 4 DC DC 12 VDC 50 mA Note A detailed description of how to configure the GPIs and assign the available software objects Function correspondingly is given in the 5D Reference manual which can be...

Page 19: ...form a system reset proceed as follows Note All device preferences will be set to factory defaults except for the network and fixed device settings 1 Switch off 2 Press and hold the RESET button using...

Page 20: ...flashing patterns Channel error Single flash of the corresponding Channel mute LED Device Error Double flash of all Channel mute LEDs Signal LED Multi color LED indicates three states Off No signal p...

Page 21: ...he device under any circumstances Refer servicing only to qualified service personnel authorized by d b audiotechnik In particular if objects or liquids have entered the device the device does not ope...

Page 22: ...from d b or downloaded from the d b website at www dbaudio com 7 2 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its oper...

Page 23: ......

Page 24: ...D2766 EN 01 05 2022 d b audiotechnik GmbH Co KG www dbaudio com...

Reviews: