background image

 

Explanation of graphical symbols

The lightning symbol within a triangle is intended to alert

the user to the presence of uninsulated "dangerous

voltages" within the unit’s chassis that may be of

sufficient magnitude to constitute a risk of electric shock

to humans.

 

The exclamation point within a triangle is intended to

alert the user to the presence of important operating and

service instructions in the literature accompanying the

product.

Before using this product, carefully read the

applicable items of the following safety instructions.

 

 

1. Keep these instructions for future reference.
2. Read these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Keep water or other liquids away from the unit. Do not place

liquid filled containers, for example beverages, on top of the

unit.

6. Do not operate the unit while it is wet or standing in liquid.
7. Always operate the unit with the chassis ground wire

connected to the electrical safety earth. Do not defeat the

safety purpose of a grounding-type plug. A grounding-type

plug has two blades and a third grounding prong. The third

prong is provided for your safety. If the provided plug does

not fit into your outlet, consult an electrician for replacement of

the obsolete outlet.

8. Do not use this unit if the power cord is damaged or frayed.

Protect the power cord from being walked upon or pinched,

particularly at the plugs and the point where it exits from the

apparatus.

9. The unit is intended for use in a 19" rack. Follow the mounting

instructions. When a rack on wheels is used, exercise caution

when moving the loaded rack to avoid injury from tipping

over.

10. Unplug this apparatus during lightning storms or when unused

for long periods of time.

 

11. Lay all cables connected to the unit carefully so that they

cannot be crushed by vehicles or other equipment and that no

one can either step on them or trip over them.

12. Refer all servicing to qualified service personnel. Servicing is

required when the apparatus has been damaged in any way

such as:

– Power-supply cord or plug is damaged.
– Liquid has been spilled into the unit.
– An object has fallen into the unit.
– The unit has been exposed to rain or moisture.
– The unit does not operate normally.
– The unit was dropped or the chassis is damaged.
– Do not remove top or bottom covers. Removal of the covers

will expose hazardous voltages. There are no user

serviceable parts inside and removal may void the warranty.

13. Use the mains plug as the disconnecting device and keep it

readily accessible. If the mains plug is not readily accessible

due to mounting in a 19" rack, then the mains plug for the

entire rack must be readily accessible.

14. An experienced user must always supervise the equipment,

especially if inexperienced adults or minors are using the

equipment.

IMPORTANT SAFETY INSTRUCTIONS

 

d&b DS20 Manual 0.1 en

- preliminary -

3

Summary of Contents for DS20

Page 1: ... preliminary DSDS20 Manual 0 1 en ...

Page 2: ...d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Straße 134 D 71522 Backnang...

Page 3: ...cord from being walked upon or pinched particularly at the plugs and the point where it exits from the apparatus 9 The unit is intended for use in a 19 rack Follow the mounting instructions When a rack on wheels is used exercise caution when moving the loaded rack to avoid injury from tipping over 10 Unplug this apparatus during lightning storms or when unused for long periods of time 11 Lay all c...

Page 4: ... OUT 1 4 9 3 4 2 DIGITAL IN 1 4 9 3 4 3 ETH1 ETH4 9 3 4 4 Mode push button 10 3 4 5 BYPASSED SUBSCRIBED IDENTIFY SYNC ERROR 10 3 5 Rear panel 11 3 5 1 ETH 5 MODE ETH 3 11 3 5 2 DIGITAL OUT 5 16 11 4 References 12 4 1 Meta data 12 4 2 DS20 Firmware update 12 5 Manufacturer s Declarations 13 5 1 EU declaration of conformity CE symbol 13 5 2 WEEE Declaration Disposal 13 Contents d b DS20 Manual 0 1 e...

Page 5: ...lies NOTICE Acoustic interference and malfunctions may occur if the unit is operated in the immediate vicinity of high frequency transmitters e g wireless microphones mobile phones etc Damage to the device is unlikely but cannot be excluded 1 2 Scope of supply Before starting up the device please verify the shipment for completeness and proper condition of the items If there is any sign of obvious...

Page 6: ... 3 AES Signal Output impedance 110 ohms Sampling rate 48 96 kHz Synchronization Milan network Network Connectors etherCON built in 5 port AVB Ethernet switch 100 1000 Mbit Controls and indicators Mode Push button Switch port modes Audio loss RGB LEDs BYPASSED SUBSCRIBED Rx subscription LED indicator green IDENTIFY SYNC ERROR LED indicator red Operating conditions Temperature range 0 C 40 C 32 F 10...

Page 7: ...ETH4 on page 9 4 Mode switch Refer to Þ Chapter 3 4 4 Mode push button on page 10 5 BYPASSED SUBSCRIBED indicators Refer to Þ Chapter 3 4 5 BYPASSED SUBSCRIBED IDENTIFY SYNC ERROR on page 10 6 IDENTIFY SYNC ERROR indicators Refer to Þ Chapter 3 4 5 BYPASSED SUBSCRIBED IDENTIFY SYNC ERROR on page 10 Rear panel 7 powerCON Mains connector socket Refer toÞ Chapter 3 3 Mains connection on page 8 8 ethe...

Page 8: ...provided Do not block or cover the rear panel vents on the side panel air intake If the DS20 is installed in sealed cabinets e g in fixed installations use additional fan modules with filters that can be easily replaced without opening the sealed cabinets 3 3 Mains connection WARNING Potential risk of electric shock The device is a protective class 1 unit A missing earth ground contact may cause d...

Page 9: ...4 The DS20 provides a 5 port AVB Ethernet switch for different network topologies redundancy and advanced functions Four connectors ETH1 ETH4 are provided on the front panel while a fifth port ETH 5 is provided on the rear panel The device supports two different switch modes which are intended for different applications and network topologies According to the mode the Ethernet ports assume differe...

Page 10: ...or 2 seconds The device enters configuration mode with the current mode selected and all LEDs will flash 2 To set the desired configuration switch mode briefly push the Mode button to step through the different switch modes The following switch mode order will apply Default PRI SEC Bypass off PRI All Bypass off PRI SEC Bypass on Þ SUBSCRIBED LED flashes PRI All Bypass on Þ SUBSCRIBED LED flashes 3...

Page 11: ...is intended for the internal Ethernet wiring within a d b Touring rack assembly 3 5 2 DIGITAL OUT 5 16 In addition six digital output connectors are provided on the rear panel to allow further AES channels to be used if more than four AES channels are required d b DS20 Manual 0 1 en preliminary 11 ...

Page 12: ...Remote network For more information please refer to the respective amplifier manuals and or the R1 Help system 4 2 DS20 Firmware update NOTICE Only use firmware files provided by d b Using firmware files not provided by d b can result in the DS20 becoming unusable Firmware update files are provided by d b at www dbaudio com We recommend you to regularly check the d b website for the latest firmwar...

Page 13: ... EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 5 2 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective nationa...

Page 14: ...D2743 EN 01 02 2019 d b audiotechnik GmbH www dbaudio com preliminary ...