d&b audiotechnik C7-SUB Manual Download Page 5

C7-SUB Manual

(3.0E) 

Page 5 of 8

Operation with D12

Selecting  C7-SUB  mode  in  the  D12  enables  up  to  two  C7-SUB
cabinets  to  be  driven  by  each  channel.  In  applications  with  low
continuous  levels  and  low  ambient  temperatures  up  to  three
cabinets per channel may be connected.

When  the  D12  is  operated  in  "Mix  TOP/SUB"  mode  C7-SUB
cabinet  and  a  respective  full  range  system  can  be  linked  together
locally  and  fed  by  a  single  4-wire  cable  from  either  amplifier
output connector.

IMPORTANT!

To apply SenseDrive for the subwoofer, EP5 connectors and 5-wire
cables  have  to  be  used.  When  operated  in  "Mix  TOP/SUB"  mode
the  subwoofer  has  to  be  fed  from  the  output  B  connector  of  the
D12 amplifier.

Controller settings

For acoustic adjustment the 100 Hz setting can be selected.

100 Hz

If the 100 Hz setting is selected, the upper operating frequency of
the  system  is  reduced  from  140  Hz  to  100  Hz.  This  setting  allows
the  C7-SUB  to  supplement  TOP  cabinets  in  full  range  mode  (i.e.
CUT not selected).

The  100  Hz  setting  may  also  be  used  with  TOP  cabinets  in  CUT
mode  to  compensate  for  room  resonances  often  found  in  the
125 Hz band.

Operation with E-PAC (Version 3 with display only)

Selecting  C7-SUB  mode  in  the  E-PAC  enables  one  C7-SUB  cabinet
to  be  driven  at  an  output  power  of  300  Watts.  We  do  not
recommend that two C7-SUB cabinets are driven in LO IMP mode as
the  6  dB  reduction  in  input  level  to  the  loudspeakers  results  in  no
gain in acoustical output.

The  100  Hz  setting  is  available.  The  characteristics  of  the  100  Hz
setting  is  explained  under  the  previous  section  "Operation  with
D12 - Controller settings".

Operation with P1200A

C7-SUB

100Hz

GR

ISP

MUTE

OVL

-12

dB

-6

+6

0

Controls on C7-SUB
controller module

Up  to  two  C7-SUB  cabinets  can  be  driven  by  each  P1200A  power
amplifier  channel  fitted  with  a  C7-SUB  controller  module.  Fitting
one  C7-SUB  and  one  TOP  controller  module  allows  a  single
mainframe to drive two C7-SUB and two TOP cabinets. All cabinets
can  be  linked  together  locally  and  fed  by  a  single  4-wire  cable
from either mainframe output connector.

The  100  Hz  setting  is  available.  The  characteristics  of  the  100  Hz
setting is explained under the previous section "Operation with D12
- Controller settings".

Summary of Contents for C7-SUB

Page 1: ...C7 SUB Manual 3 0E ...

Page 2: ...s As manufacterers we reserve the right to make alterations and modifications within the framework of legal provisions as well as changes aimed at improving quality d b audiotechnik AG Eugen Adolff Strasse 134 D 71522 Backnang Germany Telephone 49 7191 9669 0 Fax 49 7191 95 00 00 E mail docadmin dbaudio com Internet www dbaudio com References in the manual WARNING This refers to a potentially dang...

Page 3: ...n a firm surface If you place several systems on top of one another use straps to secure them against movement Only use accessories which have been tested and approved by d b for assembly and mobile deployment Pay attention to the correct application and maximum load capacity of the accessories as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure tha...

Page 4: ...d for the deployment of full range cabinets CAUTION Only operate C7 SUB cabinet with a d b D12 or E PAC amplifier in C7 SUB mode or a P1200A mainframe fitted with a C7 SUB controller module otherwise there is a risk of damaging the loudspeaker components Connections 1 2 3 4 5 1 2 3 4 5 Sense Drive n c Connector wiring The C7 SUB cabinet is fitted with a pair of EP5 connectors All pins of both conn...

Page 5: ...ay also be used with TOP cabinets in CUT mode to compensate for room resonances often found in the 125 Hz band Operation with E PAC Version 3 with display only Selecting C7 SUB mode in the E PAC enables one C7 SUB cabinet to be driven at an output power of 300 Watts We do not recommend that two C7 SUB cabinets are driven in LO IMP mode as the 6 dB reduction in input level to the loudspeakers resul...

Page 6: ... peak pink noise test signal with crest factor of 4 Input level 100 dB SPL 1m 13 dBu Polarity to controller INPUT XLR pin 2 3 LF C7 SUB subwoofer Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 400 1200 W Connections 2 x EP5 Pin assignments 3 4 and 5 Pin 5 SenseDrive D12 optional 2 x NL4 Pin assignments 2 2 Weight 49 kg 108 lb 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k C7 SUB freque...

Page 7: ...ions of these types are included provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications We herewith declare that said products are in conformity with the provisions of the following EC directives including all applicable amendments 89 336 Electromagnetic Compatibility The following standards have been applied DIN ...