d&b audiotechnik Bi8-SUB Manual Download Page 6

 

To install the fixed cable connection, proceed as follows:
Tools required: Philips screw driver (#PH2).
1. Remove the knockout opening in the cover plate 

[1] and

attach the rubber grommet 

[2] correspondingly.

2. Insert the connection cable through the rubber grommet.
3. Undo the four screws of the connector panel.
4. Connect the cable wires to the screw terminal.

Þ

 Observe the correct polarity!

5. Push the cover plate towards the connector panel until it fits

into place.

6. Finally fix the cover plate together with the connector panel

using all screws.

Step 2

Step 3

Step 4/5

Step 6

Installing the fixed cable connection

NL4 connection with cover plate

Note: Neutrik NL4FC type connectors must be used for this

option.

The cover plate is equipped with two knockout openings to allow

daisy chaining of the loudspeaker.
To use the NL4 connection, proceed in the same manner as

described in the previous section.

Step 1

NL4 cable connection with cover plate [1]

 

d&b Bi8-SUB Manual 1.1 en

6

Summary of Contents for Bi8-SUB

Page 1: ...B Bi8 SUB Manual 1 1 en...

Page 2: ...ly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your custo...

Page 3: ...B loudspeaker 5 2 1 Product description 5 2 2 Connections 5 2 3 Operation 7 2 3 1 Controller settings 8 2 4 Technical specifications 8 3 Manufacturer s declarations 9 3 1 EU conformity of loudspeakers...

Page 4: ...es as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment ar...

Page 5: ...onnections The cabinet is fitted with a pair of NL4 M connectors and a two pole screw terminal block ST All four pins of both NL4 connectors are wired in parallel The cabinet uses the pin assignments...

Page 6: ...sh the cover plate towards the connector panel until it fits into place 6 Finally fix the cover plate together with the connector panel using all screws Step 2 Step 3 Step 4 5 Step 6 Installing the fi...

Page 7: ...able diameters from 6 12 mm is enclosed as shown in the graphic opposite To install the fixed connection cable please proceed as follows Tools required Screw driver T20 Note Observe the correct polari...

Page 8: ...dB standard 43 Hz 170 Hz Frequency response 5 dB 100 Hz mode 43 Hz 125 Hz Max sound pressure 1 m free field with 10D D6 120 dB with 30D D20 122 dB with D80 122 dB SPLmax peak pink noise test signal wi...

Page 9: ...respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE...

Page 10: ......

Page 11: ...D2728 EN 01 03 2019 d b audiotechnik GmbH www dbaudio com...

Reviews: