background image

B

Bi6-SUB

Manual 1.1 en

Summary of Contents for Bi6-SUB

Page 1: ...B Bi6 SUB Manual 1 1 en ...

Page 2: ...nce When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin d...

Page 3: ...UB loudspeaker 5 2 1 Product description 5 2 2 Connections 5 2 3 Operation 7 2 3 1 Controller settings 7 2 4 Technical specifications 8 3 Manufacturer s declarations 9 3 1 EU conformity of loudspeakers CE symbol 9 3 1 1 WEEE Declaration Disposal 9 Contents d b Bi6 SUB Manual 1 1 en 3 ...

Page 4: ...ies as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visi...

Page 5: ...ith a pair of NL4 M connectors and a two pole screw terminal block ST All four pins of both NL4 M connectors are wired in parallel The cabinet uses the pin assignments 2 2 Pins 1 1 are designated to full range cabinets Cabinets with the weather resistant option WR are equipped with a fixed input cable PG type H07 RN F 2 x 2 5 mm2 AWG 13 standard length 5 5 m 18 ft Pin equivalents of the applicable...

Page 6: ...ion The Bi6 SUB loudspeaker is supplied with a cover plate 1 and a rubber grommet feed through 2 For indoor operation these items can be used to hide the connector panel if required For unprotected outdoor operation the connector panel must be covered i e both items must be used to achieve an IP degree of protection of IP34 To install the fixed cable connection proceed as follows Tools required Ph...

Page 7: ...and CSA function can be selected 100 Hz circuit If the 100 Hz circuit is selected the upper operating frequency of the system is reduced from 140 Hz to 110 Hz It can be used when actively driven Bi6 SUB subwoofers are used to supplement TOP cabinets operated in full range mode for example in a distributed sound system The 100 Hz mode can also be used to compensate for the effect of close coupling ...

Page 8: ...ith D12 D20 30D 131 dB with D80 134 dB SPLmax peak pink noise test signal with crest factor of 4 Bi6 SUB loudspeaker Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 500 2000 W Components 1 x 18 driver Connections 2 x NL4 M 1 x screw terminal ST up to 4 mm2 AWG 11 Optional fixed cable PG H07 RN F 2 x 2 5 mm2 AWG 13 5 5 m 18 ft Pin assignment NL4 M 1 1 Fixed cable PG Brown Blue Weigh...

Page 9: ... respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respe...

Page 10: ...D2716 EN 01 08 2014 d b audiotechnik GmbH www dbaudio com ...