WELCOME

Thank you for choosing a Danby appliance to provide you and your family with

all of the “Home Comfort” requirements of your home, cottage, or office. This

Owner’s Use and Care Guide will provide you with valuable information 

necessary for the proper care and maintenance of your new appliance. If 

properly maintained, your Danby appliance will give you many years of trouble

free operation. Please take a few moments to read the instructions thoroughly

and familiarize yourself with all of the operational aspects of this appliance. 

Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging,

air-processing appliance, designed to offer you the functions of; Air

Conditioning, Dehumidifying, and Independent Fan. Each individual mode is

featured with “oscillating” air swing capabilities. This unit can be conveniently

moved from room to room within your home and set up in just minutes. Imagine

the convenience of 4 Season Home Comfort at your fingertips, anywhere, 

anytime. 

For easy reference, may we suggest you attach a copy of your sales slip/receipt

to this page, along with the following information, located on the manufacturers

nameplate on the rear panel of the unit.  

Model Number:

Serial Number:

Date of Purchase:

This information will be necessary if your unit requires servicing and/or for 

general inquiries. To contact a Customer Service Representative, call Danby

TOLL FREE: 1-800-26-

(1-800-263-2629)

2

Model Number

DPAC9009

Voltage/Frequency

115V-60Hz

Noise Level

48.5 dB

Fan Speeds

3

Cooling Capacity

9000BTU

Refrigerant

R410A

Unit Weight

27.2 kg (60lbs)

Airflow CFM High/Med./Low

342 / 318 / 288

Dimensions (W) x (D) x (H)(inches)

17.2”x 15.3”x 30.5”

Dimensions (W) x (D) x (H) (mm)

475 / 460 / 870

Remote Control

Yes

Time of Day Clock

No

Auto-Timer

Yes

UNIT SPECIFICATIONS 

NOTE:

Continuing research results in steady improvement. Therefore, this information

and these specifications are subject to change without notice. 

Summary of Contents for Premiere DPAC9009

Page 1: ...isation initiale de ce produit PORTABLE AIR CONDITIONER Table of contents 1 CLIMATISEUR PORTATIF Table des mati res 13 Danby Products Ltd PO Box 1778 Guelph Ontario Canada N1H 6Z9 Danby Products Inc P...

Page 2: ...INFORMATION Electrical Specifications 3 Energy Saving Tips 4 INSTALLATION 5 Window Kit Installation 5 OPERATION Features of the Control Panel 6 Air Conditioning 7 Dehumidifier 8 Fan 8 Auto Timer 9 Rem...

Page 3: ...within your home and set up in just minutes Imagine the convenience of 4 Season Home Comfort at your fingertips anywhere anytime For easy reference may we suggest you attach a copy of your sales slip...

Page 4: ...associated with the appliance Check with a qualified service representative if in doubt that the appliance is proplery grounded 4 DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT If it is ne...

Page 5: ...o the fullest extent 5 When outdoor temperatures are cool enough turn the air conditioner off and use the FAN MODE This circulates indoor air providing some cooling comfort while utilizing less electr...

Page 6: ...least 11 8 30cm clearance between the unit and any other objects or building structures and should be installed on a level surface The unit does not have to be vented outside during Dehumidifying or...

Page 7: ...e is adjustable between 1 24 hours TEMPERATURE Adjust Used for adjusting the thermostat The default display is room temperature In cooling mode when button is pressed the set temperature is displayed...

Page 8: ...will advance to a different mode setting Cool Dehumidifier Fan Heat Auto 3 Press the appropriate or buttons Fig D1 D2 to select a suitable operating temperature setting Temperature settings are adjust...

Page 9: ...for Low and the dehumidifier operates continuously non stop regardless of ambient humidity level or set temperature FAN NOTE During Fan Mode the exhaust hose does not have to be vented outdoors 1 Pre...

Page 10: ...Timer setting is available from 1 24 hours by pressing the key To operate the hand held remote control you will require two AAA Alkaline batteries included Batteries should be replaced when a No signa...

Page 11: ...ust dirt air flow is restricted which reduces cooling efficiency The air filter should be cleaned every two 2 weeks More frequent cleaning may be necessary depending on indoor air quality NOTE The air...

Page 12: ...ing temperature is too high low Exhaust duct hose is blocked Window or door is open in room There is a heat source or too many people in the room Air intake grill is clogged Filter is too dirty Temper...

Page 13: ...tions lectrique 15 Suggestions pour conomiseur d nergie 16 INSTALLATION 17 Installation de kit de fen tre 17 UTILISATION Dispositifs du panneau de commande 18 Climatisation 19 D shumidificateur 20 Ven...

Page 14: ...ort au foyer 3 saisons port e de la main en tout temps en tout lieu Pour la r f rence ais e nous vous sugg rons de joindre une copie de votre re u de caisse et ou facture d achat cette page et d inscr...

Page 15: ...tes pas certain que les prises de courant de votre domicile sont correctement mises la terre consultez un lectricien qualifi 4 NE PAS UTILISER LES ADAPTATEURS DE FICHE OU LES CORDES DE RALLONGE AVEC...

Page 16: ...p ratures externes sont suffisamment froides placer le climatiseur hors de service et utiliser le MODE DE VENTILATEUR la position HAUTE MOYENNE ou BAS Ceci fait circuler l air l int rieur de la pi ce...

Page 17: ...t 2 mcx de 17 7 10 45cm jusqu 53 1 6 135cm Tuyay d echappement flexible 11cm bec connecteur d chappement 2 mcx de 15 3 4 45cm jusqu 51 1 5 135cm Ensemble de portes fen tre coulissantes 3 mrc de 28 1 3...

Page 18: ...nde de temporisateur Appuyez sur les boutons pour choisir le nombre d heures avant que l unit commence automatiquement fonctionner en mode conditionning d air NOTE Le temps est r glable entre 1 24 heu...

Page 19: ...lage de mode diff rent Frais Sec Ventilateur 3 Appuyer sur le touche augmenter ou diminuer R GLAGE DE TEMP RATURE Fig D pour choisir un r glage de temp rature appropri e Les r glages de temp rature so...

Page 20: ...icateur fonctionne sans interruption ind pendamment des niveaux ambiants d humidit ou r glage du temp rature FAN REMARQUE L installation du tuyau flexible pour l chappement d air n est pas requise pou...

Page 21: ...t tre ajust e Apr s 10 secondes l affichage revient la temp rature ambiante Le r glage de la minuterie disponible est de 1 24 heures en appuyant sur la touche Deux piles alcalines AAA sont requises po...

Page 22: ...ettoy aux deux 2 semaines Le nettoyage plus fr quent pourrait tre n cessaire selon la qualit de l air interne REMARQUE Le filtre air est situ la partie sup rieure arri re de l unit 1 Pour enlever le f...

Page 23: ...Le tuyau d chappement est bloqu La fen tre ou la porte de la pi ce est ouverte Il y a une source de chaleur ou trop de gens dans la pi ce La grille de prise d air est obstru e Le filtre est trop sale...

Page 24: ...UMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description Climatiseur Portatif Le num ro de mod le se trouve sur l...

Reviews: